Simulation and Phantom Studies of Contrast-Enhanced Dual Energy Mammography (CEDEM)
نویسندگان
چکیده
Contrast-enhanced dual energy mammography (CEDEM) has been shown effective in enhancing the visibility of breast cancer in diagnostic mammographic images. The simulation and phantom studies of CEDEM were implemented to enhance acquisition techniques of a dedicated cone-beam breast CT scanner fabricated in our laboratory. CEDEM images were computersimulated numerically, and the results were compared and validated with physical experiments using a custom-made breast-equivalent phantom with pseudo anatomical structures. The technique factors to be optimized included lowand high-energy x-ray spectra (kVp), spectra filters and mAs (x-ray tube current × scan time in second). Signal-difference-to-noise ratio (SDNR) of the logweighted subtracted image was computed to optimize subtraction parameters using several combinations of breast compositions and thicknesses. Both simulation and phantom studies suggest that 40 kVp (filtered with 1.5 mm Al) and 50 kVp (filtered with 1.5 mm Al and 0.3 mm Cu) were the optimal spectra with the highest SDNR on the dual energy subtracted image of a 6-cm, 50% glandular breast. Breast composition and thickness were found to have little influence on the optimized technique factors. We conclude that the simulation and phantom studies demonstrated the effectiveness of CEDEM using the prototype breast CT scanner in producing high-quality, lesion-enhanced images.
منابع مشابه
ارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب مختلف به صورت همزمان از بافت پستان با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی
Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. Materials and methods: A breast phantom was designed and b...
متن کاملEstimating Breast Thickness for Dual-Energy Subtraction in Contrast-Enhanced Digital Mammography: A Theoretical Model
Dual-energy contrast-enhanced digital mammography (DE CE-DM) images the perfusion and vasculature of the breast using an iodinated contrast agent. High-energy (HE) and low-energy (LE) images of the breast are acquired; the DE image is obtained by a weighted logarithmic subtraction of the image pair. We hypothesized that the optimal DE subtraction weighting factor, w, is dependent on three param...
متن کاملSimulation and patient studies of scatter correction in cardiac SPECT imaging
Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...
متن کاملEstimating breast thickness for dual-energy subtraction in contrast-enhanced digital mammography using calibration phantoms
Dual-energy contrast-enhanced digital mammography (DE CE-DM) uses an iodinated contrast agent to image the perfusion and vasculature of the breast. DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. We hypothesized that the optimal DE subtraction weighting factor is thicknessdependent, and developed a method for determining brea...
متن کاملThe impact of calibration phantom errors on dual-energy digital mammography.
Microcalcification is one of the earliest and main indicators of breast cancer. Because dual-energy digital mammography could suppress the contrast between the adipose and glandular tissues of the breast, it is considered a promising technique that will improve the detection of microcalcification. In dual-energy digital mammography, the imaged object is a human breast, while in calibration meas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008