Accuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.

نویسندگان

  • Jin Jiang
  • Xin Kang
  • Qiao Lin
  • Yuanjun Teng
  • Liping An
  • Jingling Ma
  • Jing Wang
  • Yayi Xia
چکیده

Patient-specific instrumentation (PSI) has recently been introduced to improve the alignment following total knee arthroplasty (TKA). However, controversy remains between PSI and conventional instrumentation. The aim of this study is to compare the accuracy of PSI with conventional instruments for total knee arthroplasty (TKA). A systematic literature search was performed in databases including PubMed, the Cochrane Library, EMBASE, and Web of Science. All of the available randomized, controlled trials (RCTs) or non-randomized, controlled trials (nRCTs) comparing PSI with conventional instruments for TKA were identified. A statistical analysis was performed of this meta-analysis. Eighteen studies with 2417 patients were included in the authors' final analysis. The results of the meta-analysis demonstrated that there were no statistical differences in outliers of the mechanical axis (risk ratio [RR], 0.84; 95% confidence interval [CI], 0.61-1.11), the femoral component in the coronal (RR, 0.56; 95% CI, 0.32-1.05) and sagittal (RR, 0.83; 95% CI, 0.60-1.14) plane, the tibial component in the coronal (RR, 0.84; 95% CI, 0.52-1.35) and sagittal (RR, 1.04; 95% CI, 0.69-1.55) plane, and the femoral component rotation (RR, 1.02; 95% CI, 0.57, 1.83) between the 2 groups. In addition, subgroup analysis showed that the study design and imaging used for preoperative scanning did not affect the outcome of the alignment, but a different PSI system might. The authors' meta-analysis indicated that the accuracy of PSI was not superior to conventional instruments for patients undergoing TKA. Future RCTs should focus on functional outcomes and component survivorship with mid- to long-term follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Comparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty

Purpose The KneeAlign2 (KA2, OrthoAlign Inc.) accelerometer-based portable navigation system and patient-specific instrumentation (PSI; Signature, ZimmerBiomet) are widely used for ideal femoral component alignment in total knee arthroplasty (TKA). However, there has been no comparative study of the KA2 system, PSI, and conventional intramedullary instrumentation (CON). The purpose of this stud...

متن کامل

[Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].

Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the litera...

متن کامل

Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty

Background and purpose - Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. Patients and methods - We identified randomized and quasi-randomized...

متن کامل

Patient-specific instrumentation for total knee replacement verified by computer navigation: a case report.

Patient-specific instrumentation (PSI) enables better restoration of the mechanical axis in total knee replacement (TKR) than conventional instrumentation (alignment guides) does. We verified the accuracy of the PSI by computer navigation. The PSI jigs were accurate only if they were pinned accurately onto the distal femur and proximal tibia. Any slight malposition of the jigs leads to malalign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 4  شماره 

صفحات  -