Challenges facing quantification of rat locomotion along beams of varying widths.
نویسندگان
چکیده
Optoelectronic motion capture systems have been widely used to investigate temporal gait parameters in humans and animals in order to understand function and behavioural attributes of different pathologies, e.g. Parkinson's disease (PD). The aim of the present paper was to investigate the practicality of utilising this system to investigate the effects of a unilateral 6-hydroxydopamine (6-OHDA) lesion on rat locomotion while walking on beams of varying widths (graduated, narrow, and wide). Temporal gait parameters of ten male Lister Hooded rats (five controls and five hemiparkinsonian) were observed using passive markers placed in locations that were representative of their four limbs and their body axis. The results demonstrate that marker-based motion capture can provide an effective and simple approach to quantifying temporal gait parameters for rat models of PD. They also reveal how the width of the path affects the locomotion in both experimental cohorts. Such measurements can be compared with human motion analysis to explore correlations between the animal model and human behaviour, which is an important step for translational medicine.
منابع مشابه
Free Vibration Analysis of Functionally Graded Materials Non-uniform Beams
In this article, nonuniformity effects on free vibration analysis of functionally graded beams is discussed. variation in material properties is modeled after Powerlaw and exponential models and the non-uniformity is assumed to be exponentially varying in the width along the beams with constant thickness. Analytical solution is achieved for free vibration with simply supported conditions. It is...
متن کاملServiceability Response of Rehabilitated Unbonded Post-tensioned Indeterminate I-Beams Consisting UHSSCC
The ultra-high strength self-compacting concrete, UHSSCC is the new generation type of concrete with a compressive strength higher than 80MPa. The application of this type of concrete on the serviceability state in CFRP strengthened unbonded post-tensioned indeterminate I-beam is monitored and the results are compared theoretically using different standards. For this aim, full scale I-beam of 9...
متن کاملStiffness Matrices for Axial and Bending Deformations of Non-Prismatic Beams with Linearly Varying Thickness
Siffness matrices for axial and bending deformations of a beam having a rectangular cross sectional area of constant width and linearly varying thickness are developed. A consistant load vector for a uniformly distributed lateral load is also calculated, using the principal of potential energy. The matrices are used to obtain numerical results for a variety of beams with non-uniform thickness t...
متن کاملThe Contribution of Upper Body Movements to Dynamic Balance Regulation during Challenged Locomotion
Recent studies suggest that in addition to movements between ankle and hip joints, movements of the upper body, in particular of the arms, also significantly contribute to postural control. In line with these suggestions, we analyzed regulatory movements of upper and lower body joints supporting dynamic balance regulation during challenged locomotion. The participants walked over three beams of...
متن کاملChallenges Facing the Application of ICTs in Rural Areas of Iran
The major purpose of this study was conducted to identify the challenges in application of ICTs inrural areas of Iran. A questionnaire was developed and data collected from 187 extensionspecialists. The challenges was categorized by using factor analysis and results show challengeswere classified into organizational, technical, social, financial, regulatory and human factors byorder of their im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 224 11 شماره
صفحات -
تاریخ انتشار 2010