Contrast-enhanced spiral CT of the head and neck: comparison of contrast material injection rates.

نویسندگان

  • R Groell
  • P Willfurth
  • G J Schaffler
  • R Mayer
  • F Schmidt
  • M M Uggowitzer
  • M Tillich
  • B Genser
چکیده

BACKGROUND AND PURPOSE Contrast-enhanced spiral CT studies of the head and neck are performed frequently using contrast material volumes of approximately 30 g iodine and a scan delay of 30-45 seconds. Because little is known about the effects of contrast material injection rates on tissue enhancement, this was prospectively investigated in our study. METHODS Ninety-seven patients underwent spiral CT of the head and neck. Each patient was assigned randomly to one of four groups who received 100 mL of nonionic contrast material (300 mg I/mL) at different monophasic injection flow rates with 1.5, 2, 3, and 4 mL/s. Scanning started after a constant delay of 35 seconds. The attenuation of the carotid artery, jugular vein, and sternocleidomastoid muscle was measured over time and the attenuation of the submandibular and thyroid gland was evaluated. Vascular attenuation of at least 150 HU was considered to be sufficient. RESULTS The mean scan time was 33+/-5 seconds. The study, using an injection rate of 2 mL/s, showed the longest time of sufficient overall (arterial and venous) vessel attenuation (27+/-4 seconds, P< or =.008). The injection flow rate did not influence significantly muscular attenuation (mean enhancement during scan time: 9+/-7 HU). The 1.5 mL/s protocol showed the lowest attenuation values of the submandibular gland (81+/-12 HU) and the highest attenuation values of the thyroid gland (164+/-22 HU), but the attenuation of the thyroid gland was not statistically different from that revealed by the 2 mL/s protocol. CONCLUSION Using 100 mL of intravenous contrast material with 300 mg I/mL for spiral CT studies of the entire head and neck, the optimal injection flow is 2 mL/s, whereas lower flow rates resulted in insufficient venous enhancement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of contrast agent on delivered dose during diagnostic imaging of thoracic region

This study evaluated the impact of contrast material on the estimation of absorbed dose due to computed tomography pulmonary angiography (CTPA) using the ICRP reference phantoms. To address this issue, we modified the previously developed physiologically based pharmacokinetic (PBPK) model to be conformed to the ICRP reference phantoms. Regarding the standard contrast material injection protocol...

متن کامل

The feasibility of direct treatment planning via contrast-enhanced computed tomography: an evaluation of dose differences based on the dimensional dose distribution comparison method

Background: We used a MapCHECK software-based dimensional dose distribution comparison method capable of evaluating point-to-point geometrical dose differences in volume to determine whether doses obtained from an enhanced computed tomography (CT)-based treatment plan, which better defines the target regions and organs at risk, differs from doses obtained from plain CT and then evaluated the fe...

متن کامل

Contrast-Induced Nephropathy Following CT Scan and Its Associated Factors

Background and purpose: Contrast-induced nephropathy (CIN) as a common complication of administration of contrast media (CM) is a major source of hospital morbidity and mortality. The aim of this study was to determine the incidence of CIN after contrast-enhanced CT scan and identifying the related risk factors. Materials and methods: A cross-sectional study was carried out in 100 patients att...

متن کامل

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Synovial Sarcoma of the Head and Neck: A Case of Childhood Soft Tissue Sarcoma

Although rare, synovial sarcoma is the most common malignant non-rhabdomyosarcomatous soft tissue sarcoma in children and adolescents. Synovial sarcoma typically involves the soft tissues of the extremities, especially near large joints, but it can occur anywhere in the body in locations far from joint spaces. Although this tumor typically affects adults in their fourth decade of life, nearly h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 1999