MR Imaging at Sub-Millisecond Frame Rates
نویسندگان
چکیده
(left) and the same sequence modified to enable acquisition of an image during the flyback of the EPI pulse sequence, in between RF pulses. The blipped gradient is not set to the same scale in the two figures. The sequence allows k-space to be traveled along the optimal line needed to compensate for the RF coil phase during each flyback, and then return to the proper position for the RF pulse generation. a b
منابع مشابه
Faster than real-time: confocal linescan systems provide ideal conditions for millisecond-resolution physiological imaging
The LSM 5 LIVE is a new design for fast confocal imaging, which acquires images at extremely high frame rates and allows experiments not possible in the past, while maintaining the advantages of conventional scanning systems, such as adjustable confocal apertures and scalable frame formats with pan and zoom. Additionally, the LSM 5 LIVE offers fast and sensitive parallel acquisition with charge...
متن کاملMagneto-optical imaging of thin magnetic films using spins in diamond
Imaging the fields of magnetic materials provides crucial insight into the physical and chemical processes surrounding magnetism, and has been a key ingredient in the spectacular development of magnetic data storage. Existing approaches using the magneto-optic Kerr effect, x-ray and electron microscopy have limitations that constrain further development, and there is increasing demand for imagi...
متن کاملHybrid Utrasound and MRI Acquisitions for High-Speed Imaging of Respiratory Organ Motion
Magnetic Resonance (MR) imaging provides excellent image quality at a high cost and low frame rate. Ultrasound (US) provides poor image quality at a low cost and high frame rate. We propose an instance-based learning system to obtain the best of both worlds: high quality MR images at high frame rates from a low cost single-element US sensor. Concurrent US and MRI pairs are acquired during a rel...
متن کاملInternational Congress on Photonics in Europe Collocated with LASER 2015
Quantitative confocal fluorescence microscopy without scanning is developed for the study of fast dynamical processes via massively parallel Fluorescence Correlation Spectroscopy (FCS). The potential of this approach is demonstrated using live salivary glands from Drosophila third instar larvae expressing a fluorescently-tagged transcription factor. This approach paves the way for quantitative ...
متن کاملAdaptive Sampling for Low Latency Vision Processing
In this paper we describe a close-to-sensor low latency visual processing system. We show that by adaptively sampling visual information, low level tracking can be achieved at high temporal frequencies with no increase in bandwidth and using very little memory. By having close-to-sensor processing, image regions can be captured and processed at millisecond sub-frame rates. If spatiotemporal reg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008