Fast, high-resolution surface potential measurements in air with heterodyne Kelvin probe force microscopy.
نویسندگان
چکیده
Kelvin probe force microscopy (KPFM) adapts an atomic force microscope to measure electric potential on surfaces at nanometer length scales. Here we demonstrate that Heterodyne-KPFM enables scan rates of several frames per minute in air, and concurrently maintains spatial resolution and voltage sensitivity comparable to frequency-modulation KPFM, the current spatial resolution standard. Two common classes of topography-coupled artifacts are shown to be avoidable with H-KPFM. A second implementation of H-KPFM is also introduced, in which the voltage signal is amplified by the first cantilever resonance for enhanced sensitivity. The enhanced temporal resolution of H-KPFM can enable the imaging of many dynamic processes, such as such as electrochromic switching, phase transitions, and device degredation (battery, solar, etc), which take place over seconds to minutes and involve changes in electric potential at nanometer lengths.
منابع مشابه
The effect of patch potentials in Casimir force measurements determined by heterodyne Kelvin probe force microscopy.
Measurements of the Casimir force require the elimination of the electrostatic force between the surfaces. However, due to electrostatic patch potentials, the voltage required to minimize the total force may not be sufficient to completely nullify the electrostatic interaction. Thus, these surface potential variations cause an additional force, which can obscure the Casimir force signal. In thi...
متن کاملPotential sensitivities in frequency modulation and heterodyne amplitude modulation Kelvin probe force microscopes
In this paper, the potential sensitivity in Kelvin probe force microscopy (KPFM) was investigated in frequency modulation (FM) and heterodyne amplitude modulation (AM) modes. We showed theoretically that the minimum detectable contact potential difference (CPD) in FM-KPFM is higher than in heterodyne AM-KPFM. We experimentally confirmed that the signal-to-noise ratio in FM-KPFM is lower than th...
متن کاملContrast distortion induced by modulation voltage in scanning capacitance microscopy
Related Articles Internal resonance based sensing in non-contact atomic force microscopy Appl. Phys. Lett. 101, 053106 (2012) Joint strength measurements of individual fiber-fiber bonds: An atomic force microscopy based method Rev. Sci. Instrum. 83, 073902 (2012) Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and hi...
متن کاملEffects of elastic and inelastic interactions on phase contrast images in tapping-mode scanning force microscopy
Related Articles Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis Rev. Sci. Instrum. 83, 063702 (2012) High-speed Lissajous-scan atomic force microscopy: Scan pattern planning and control design issues Rev. Sci. Instrum. 83, 063701 (2012) High potential sensitiv...
متن کاملGold nanoparticle coated silicon tips for Kelvin probe force microscopy in air.
The tip apex dimensions and geometry of the conductive probe remain the major limitation to the resolution of Kelvin probe force microscopy (KPFM). One of the possible strategies to improve the spatial resolution of surface potential images consists in the development of thinner and more durable conductive tips. In an effort to improve the lateral resolution of topography and surface potential ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nanotechnology
دوره 27 24 شماره
صفحات -
تاریخ انتشار 2016