Spectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling cochlear implants.

نویسندگان

  • Tim Green
  • Andrew Faulkner
  • Stuart Rosen
چکیده

Four-band and single-band noise-excited vocoders were used in acoustic simulations to investigate spectral and temporal cues to melodic pitch in the output of a cochlear implant speech processor. Noise carriers were modulated by amplitude envelopes extracted by half-wave rectification and low-pass filtering at 32 or 400 Hz. The four-band, but not the single-band processors, may preserve spectral correlates of fundamental frequency (F0). Envelope smoothing at 400 Hz preserves temporal correlates of F0, which are eliminated with 32-Hz smoothing. Inputs to the processors were sawtooth frequency glides, in which spectral variation is completely determined by F0, or synthetic diphthongal vowel glides, whose spectral shape is dominated by varying formant resonances. Normal listeners labeled the direction of pitch movement of the processed stimuli. For processed sawtooth waves, purely temporal cues led to decreasing performance with increasing F0. With purely spectral cues, performance was above chance despite the limited spectral resolution of the processors. For processed diphthongs, performance with purely spectral cues was at chance, showing that spectral envelope changes due to formant movement obscured spectral cues to F0. Performance with temporal cues was poorer for diphthongs than for sawtooths, with very limited discrimination at higher F0. These data suggest that, for speech signals through a typical cochlear implant processor, spectral cues to pitch are likely to have limited utility, while temporal envelope cues may be useful only at low F0.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speech, Hearing and Language: work in progress Volume 13 Spectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling (CIS) cochlear implants

Four-band and single-band noise-excited vocoders were used in acoustic simulations to investigate spectral and temporal cues to melodic pitch in the output of a cochlear implant speech processor. Noise carriers were modulated by amplitude envelopes extracted by half-wave rectification and low-pass filtering at 32 or 400 Hz. The fourband, but not the single-band processors, may preserve spectral...

متن کامل

Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants.

The limited spectral resolution of cochlear implant systems means that voice pitch perception depends on weak temporal envelope cues. Enhancement of such cues was investigated in implant users and in acoustic simulations. Subjects labeled the pitch movement of processed synthetic diphthongal glides. In standard processing, noise carriers (simulations) or pulse trains (implant users) were modula...

متن کامل

Enhancement of temporal periodicity cues in cochlear implants: effects on prosodic perception and vowel identification.

Standard continuous interleaved sampling processing, and a modified processing strategy designed to enhance temporal cues to voice pitch, were compared on tests of intonation perception, and vowel perception, both in implant users and in acoustic simulations. In standard processing, 400 Hz low-pass envelopes modulated either pulse trains (implant users) or noise carriers (simulations). In the m...

متن کامل

Phonetic cues are weighted differently when spectral resolution is degraded

Two experiments were conducted to test the hypothesis that listeners would modify perceptual strategies for phonetic identification if the spectrum of a speech signal was degraded. The contrasts between tense and lax vowels and between word-final s/z were selected because of the primacy of spectral cues and redundancy of temporal cues used in normal listening situations. In the first experiment...

متن کامل

The effect of spectral smearing on the identification of pure F0 intonation contours in vocoder simulations of cochlear implants.

OBJECTIVES Performance of cochlear implant (CI) users on linguistic intonation recognition is poorer than that of normal-hearing listeners, due to the limited spectral detail provided by the implant. A higher spectral resolution is provided by narrow rather than by broad filter slopes. The corresponding effect of the filter slope on the identification of linguistic intonation conveyed by pitch ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 112 5 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2002