Parameters for neodymium-YAG laser trabeculotomy: an in-vitro study.
نویسندگان
چکیده
A Biophysic Médical Nanolas Q-Switched pulsed neodymium-YAG laser has been used to produce lesions in human trabecular meshwork in vitro. Sectors of corneoscleral tissue containing trabecular meshwork were suspended in a waterbath which had had a Trokel gonioscopic contact lens mounted into one side by means of a watertight seal. The laser was used to produce lesions in the trabecular meshwork on either side of each specimen. The energy levels delivered ranged from 0.5 to 7.0 mJ, and convergence angles of 10 degrees and 18 degrees were employed. The energy levels required to produce discrete lesions into the canal of Schlemm without perforating the underlying sclera were 3.0-5.0 mJ at the 10 degrees convergence angle and 4.0-6.0 mJ at the 18 degrees convergence angle setting. It is recommended that such data be determined for each type of laser prior to attempting short-pulsed laser internal trabeculotomy in patients with glaucoma.
منابع مشابه
Pulsed neodymium-YAG laser trabeculotomy: energy requirements and replicability.
Short pulsed laser trabeculotomy has been shown to reduce intraocular pressure in patients with primary open angle glaucoma. This study seeks to determine the energy levels required to produce a fistula into the canal of Schlemm for four different Q-switched neodymium-YAG lasers. The laser was fired at fixed human trabecular meshwork specimens at a range of energy settings for each laser and th...
متن کاملneodymium/YAG laser trabeculotomy
Laser trabeculotomies produced by directing a pulsed neodymium/YAG laser beam at specimens of human anterior chamber angle obtained post mortem or after enucleation were studied by light microscopy and by scanning and transmission electron microscopy to assess the dimensions of the openings created in the trabecular meshwork, their penetrance to the canal of Schlemm, and the extent or absence o...
متن کاملIn vitro studies with a pulsed neodymium/YAG laser.
The relationships between the destructive effects of Q-switched Nd/YAG laser pulses and a number of experimental parameters were studied for various target materials including in particular excised, fixed samples of human trabecular meshwork. The laser parameters altered were the pulse energy, the convergence angle of the focused beam, and the position of the focus of the beam relative to the t...
متن کاملIn vitro Evaluation of Dentin Surface Irradiated by Neodymium-doped: Yttrium Aluminum Garnet Laser (Nd: YAG) Using Scanning Electron Microscopy
Introdouction: Dentinal hypersensitivity (DH) is one of the most painful chronic problems reported in dental offices. Various methods have been applied for the treatment of DH. However, majority of them are either ineffective or last for a short period of time. It has been reported that lasers, particularly Neodymium- doped: Yttrium Aluminum Garnet laser (Nd: YAG), can be helpful in the treatme...
متن کاملShort-pulsed neodymium-YAG laser trabeculotomy. An in vivo morphological study in the human eye.
The in vivo response to short-pulsed Nd-YAG laser damage to the trabecular meshwork has not been studied in the human eye. The nature of the response will determine the potential efficacy of this treatment for glaucoma. We have investigated short-pulsed laser trabeculotomy lesions created in the trabecular meshwork of four human eyes within 18 hr prior to enucleation for intraocular melanoma. S...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 71 10 شماره
صفحات -
تاریخ انتشار 1987