Diagnostic Ability and Repeatability of a New Supra-Threshold Glaucoma Screening Program in Standard Automated Perimetry

نویسندگان

  • Natsumi Takahashi
  • Kazunori Hirasawa
  • Miki Hoshina
  • Masayuki Kasahara
  • Kazuhiro Matsumura
  • Nobuyuki Shoji
چکیده

PURPOSE We assess the diagnostic ability and repeatability of a new suprathreshold glaucoma screening test (GST) comprising 28 test points and a 1-of-3 sampling strategy at 95% of the normal limit for standard automated perimetry (SAP) in early to advanced glaucoma. METHODS This prospective cross-sectional study included 96 eyes of patients with early, moderate, or advanced glaucoma and 37 eyes of normal controls. Participants were evaluated by the G-Dynamic threshold test once and the GST twice, in random order, using the Octopus 600 perimeter. The diagnostic ability of GST was assessed by comparison with the G-Dynamic threshold obtained by receiver operating characteristic analysis. Repeatability was assessed by κ statistics for agreement on glaucoma diagnosis and each test point. RESULTS Although the G-Dynamic test exhibited significantly higher areas under the curve (AUC) than the GST1st (P = 0.009) in early glaucoma, there were no significant differences in any other AUCs between the two methods. The κ values for repeatability of glaucoma diagnosis and each test point were 0.747 to 1.0 and 0.537 to 1.0, respectively. The duration of the GST in the control and early glaucoma groups was less than a minute, while that in the moderate and advanced glaucoma groups was within 1.5 minutes. CONCLUSION The diagnostic ability of the new suprathreshold GST for early to advanced glaucoma was high, with moderate to strong repeatability and short test duration. TRANSLATIONAL RELEVANCE There currently are no prominent suprathreshold screening strategies using SAP. The GST would be an effective clinical method for glaucoma screening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compass: Clinical Evaluation of a New Instrument for the Diagnosis of Glaucoma

AIMS To evaluate Compass, a new instrument for glaucoma screening and diagnosis that combines scanning ophthalmoscopy, automated perimetry, and eye tracking. MATERIALS AND METHODS A total of 320 human subjects (200 normal, 120 with glaucoma) underwent full ophthalmological evaluation and perimetric evaluation using the Humphrey SITA standard 24° test (HFA), and the Compass test that consisted...

متن کامل

A comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.

Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...

متن کامل

Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability

PURPOSE We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). METHODS A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimul...

متن کامل

The repeatability of mean defect with size III and size V standard automated perimetry.

PURPOSE The mean defect (MD) of the visual field is a global statistical index used to monitor overall visual field change over time. Our goal was to investigate the relationship of MD and its variability for two clinically used strategies (Swedish Interactive Threshold Algorithm [SITA] standard size III and full threshold size V) in glaucoma patients and controls. METHODS We tested one eye, ...

متن کامل

High spatial resolution automated perimetry in glaucoma.

BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017