Is pulse synchronized pneumotonometry more reproducible than routine pneumotonometry and more in agreement with Goldmann applanation tonometry?
نویسندگان
چکیده
PURPOSE This study compared the variability of intraocular pressure (IOP) measurements taken with pulse synchronized pneumotonometry (PNT) and with routine PNT (without pulse synchronization) and evaluated the agreement between PNT and Goldmann applanation tonometry (GAT). METHODS In this prospective study, 148 eyes from 78 patients were enrolled. Patients were randomized into two groups. In the first group (A), the sequence of measurements was pulse synchronized PNT, routine PNT, and GAT. In the second group (B), the sequence of measurements was routine PNT, pulse synchronized PNT, and GAT. The mean of three measurements was averaged for PNT and GAT. All the measurements were performed by the same investigator, who was masked to GAT measurements. The mean IOP measurements and intrapatient standard deviations among the three tonometers were compared using analysis of variance measurement. Bland & Altman plots were used to assess the agreement between PNT and GAT. RESULTS The variability of IOP measurements taken with pulse synchronized PNT was significantly lower than with routine PNT in both groups (1.2+/-0.7 vs 1.3+/-0.7 mmHg in group A and 1.1+/-0.9 vs 1.3+/-1.0 mmHg in group B [p<0.001], respectively). PNT measurements with and without pulse synchronization were on average +/-2 mmHg higher than GAT measurements in both groups (p<0.001). The 95% limits of agreement between PNT and GAT varied between -3.8 and 8.5 mmHg. CONCLUSIONS Pulse synchronized PNT gives more reproducible measurements than routine PNT. The agreement between PNT and GAT is poor.
منابع مشابه
[Comparison of dynamic contour tonometry, Goldmann and pneumotonometer in ocular hypertension patients and their relationship to pachymetry and ocular pulse amplitude].
PURPOSE To determine the relationship between dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT) and pneumotonometry (PNT) in ocular hypertension patients (OHT) and their relationship to central corneal thickness (CCT) and ocular pulse amplitude (OPA). METHODS Sixty patients (101 eyes) with intraocular pressure (IOP) ≥21 mmHg using GAT and normal appearing optic nerve heads...
متن کاملThe influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.
AIMS To evaluate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT). METHODS CCT was recorded for either eye (randomly selected) of each of 105 untreated patients with ocular hypertension and glaucoma attending...
متن کامل[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].
PURPOSE To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomiz...
متن کاملApplanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods
PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...
متن کاملNoninvasive intraocular pressure measurements in mice by pneumotonometry.
PURPOSE To develop a reliable, noninvasive, continuous, and easily implemented system for measuring intraocular pressure (IOP) in mice. METHODS Pneumotonometry was adapted for measurement of mouse IOP. Measurements were compared with those obtained with the servo-null micropipette system (SNMS) and with direct anterior chamber cannulation. Heart rate was monitored by the precordial pulse, EKG...