Quantum cascade laser sensor for SO2 and SO3 for application to combustor exhaust streams.

نویسندگان

  • Wilson T Rawlins
  • Joel M Hensley
  • David M Sonnenfroh
  • David B Oakes
  • Mark G Allen
چکیده

We have demonstrated a high-sensitivity, room-temperature quantum-cascade (QC) laser sensor for detection of SO2 and SO3 under conditions relevant to aircraft test combustor exhaust. Two QC lasers probe infrared absorption features at 7.50 and 7.16 microm for SO2 and SO3, respectively, with a common dual-beam detection system. We inferred a noise-equivalent absorbance of approximately 1 x 10(-4) Hz(-1/2). We have demonstrated detection limits for both SO2 and SO3 of 1-2 ppmv m/Hz(1/2) (where ppmv is parts in 10(6) by volume) for 300 torr, elevated temperature, and path lengths near 1 m. This level of sensitivity permits measurement of < 1 ppmv of SO2 and SO3 at these conditions with modest signal averaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gaseous SO3 and H2SO4 in the exhaust of an aircraft gas turbine engine: measurements by CIMS and implications for fuel sulfur conversion to sulfur (VI) and conversion of SO3 to H2SO4

An estimation of the conversion efficiency (e) of fuel sulfur to SO3 and H2SO4, where e=([SO3]+[H2SO4])/[ST] and [ST] is the total sulfur atom concentration in the exhaust at the exit of an aircraft gas-turbine combustor, was derived from measurements by comparison with model results. The major results of the presented CIMS experiments and their interpretation with a model simulation are: (i) T...

متن کامل

Spectroscopic trace-gas sensor with rapidly scanned wavelengths of a pulsed quantum cascade laser for in situ NO monitoring of industrial exhaust systems

Development of a pulsed quantum cascade laser (QCL)-based spectroscopic trace-gas sensor for sub-part-permillion detection of nitric oxide (NO) and capable of monitoring other molecular species such as CO2, H2O, and NH3 in industrial combustion exhaust systems is reported. Rapid frequency modulation is applied to the QCL to minimize the influence of fluctuating non-selective absorption. A novel...

متن کامل

Temperature Effect on THz Quantum Cascade Lasers

A simple semi-phenomenological model, which accurately predicts the dependence of thresholdcurrent for temperature of Resonant-phonon three well quantum cascade laser based on verticaltransitions is offered. We found that, the longitude optical phonon scattering of thermally excitedelectrons is the most important limiting factor for thermal performance of high frequency THz QCLs.In low frequenc...

متن کامل

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

Fluorescent probe for biological gas SO2 derivatives bisulfite and sulfite.

A coumarin-hemicyanine dye was reported for ratiometric fluorescent detection of SO2 derivatives HSO3(-) and SO3(2-) based on a novel addition-rearrangement cascade reaction.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 44 31  شماره 

صفحات  -

تاریخ انتشار 2005