Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.

نویسندگان

  • Hiroshi Watabe
  • Hiroshi Jino
  • Naoki Kawachi
  • Noboru Teramoto
  • Takuya Hayashi
  • Youichiro Ohta
  • Hidehiro Iida
چکیده

UNLABELLED Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of 15O-water in the myocardium, the image quality of 15O-water is limited, impeding the computation of MBF and perfusable tissue fraction at the voxel level. We implemented the basis function method for generating parametric images of MBF, perfusable tissue fraction, and arterial blood volume (Va) with 15O-water and PET. The basis function method linearizes the solution of the 1-tissue-compartment model, which results in a computationally much faster method than the conventional nonlinear least-squares fitting method in estimating the parameters. METHODS To validate the basis function method, we performed a series of PET studies on miniature pigs (n = 7). After acquisition of the transmission scan for attenuation correction and the 15O-CO scan for obtaining the blood-pool image, repeated PET scans with 15O-water were obtained with varying doses of adenosine or CGS-21680 (selective adenosine A(2a) receptor agonist). MBF, perfusable tissue fraction, and Va values of the myocardial region for each scan were computed using the basis function method and the nonlinear least-squares method, and the parameters estimated by the 2 methods were compared. RESULTS MBF images generated by the basis function method demonstrated an increase in blood flow after administration of adenosine or CGS-21680. The MBF values estimated by the basis function method and by the nonlinear least-squares method correlated strongly. CONCLUSION The basis function method produces parametric images of MBF, perfusable tissue fraction, and Va with 15O-water and PET. These images will be useful in detecting regional myocardial perfusion abnormalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxygen-15-water PET assessment of muscular blood flow in peripheral vascular disease.

UNLABELLED To assess quantitatively regional nutritive muscular blood flow in patients with peripheral vascular disease (PVD), we evaluated the utility of PET with 15O-water. METHODS Eight healthy volunteers and 16 patients with angiographically proven PVD were studied. Regional blood flow of the calf was measured with 15O-water PET during rest, after intra-arterial infusion of prostaglandin ...

متن کامل

Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR

BACKGROUND The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mea...

متن کامل

Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

BACKGROUND Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from stand...

متن کامل

Quantification of myocardial blood flow with 82Rb: Validation with 15O-water using time-of-flight and point-spread-function modeling

BACKGROUND We quantified myocardial blood flow with (82)Rb PET using parameters of the generalized Renkin-Crone model estimated from (82)Rb and (15)O-water images reconstructed with time-of-flight and point spread function modeling. Previous estimates of rubidium extraction have used older-generation scanners without time-of-flight or point spread function modeling. We validated image-derived i...

متن کامل

Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 46 7  شماره 

صفحات  -

تاریخ انتشار 2005