Use of porous trabecular metal augments with impaction bone grafting in management of acetabular bone loss

نویسندگان

  • W Steven Borland
  • Raj Bhattacharya
  • James P Holland
  • Nigel T Brewster
چکیده

BACKGROUND The use of impaction grafting in revisions with larger acetabular bone defects has mixed outcomes and sometimes high failures rates. PATIENTS AND METHODS This prospective, single-center study involved a consecutive series of 24 patients who underwent complex reconstruction of the acetabulum using a trabecular metal augment, impaction bone grafting, and a cemented high-density polyethylene cup. Patients were followed for median 5 (3-7) years. RESULTS The 2-year WOMAC pain, function, and stiffness scores improved, as did certain components (bodily pain, physical function, role physical, role emotional, physical component score, and social function) of the SF-36 (p < 0.05). 23 of the patients were very satisfied with the overall outcome of the surgery and would have undergone the surgery again for a similar problem, and 19 reported great improvement in their quality of life after surgery. Radiographs at the latest follow-up revealed incorporation of the augment with mean change in acetabular component inclination of less than 1 degree (p > 0.05) and cup migration of less than 5 mm in both horizontal and vertical axes (p > 0.05). 1 patient required further revision at 13 months and was found to have a fractured augment at re-revision. INTERPRETATION This study shows that trabecular metal augments are effective in filling the bone defect and provide a stable foundation for impaction bone grafting. We found satisfactory clinical and radiographic results using this technique, with low failure rate at a median follow-up time of 5 years.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Porous metal augments: big hopes for big holes.

The majority of acetabular defects can be reconstructed with a hemispherical acetabular component alone. However, severe bone loss encountered at the time of revision acetabular surgery can result in compromised initial fixation leading to component micromotion, failure of bone ingrowth, and mechanical failure. Porous acetabular augments offer a potential solution to enhance initial component f...

متن کامل

Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up

PURPOSE High rates of mechanical failure have been reported in type III acetabular defects. Recently porous trabecular metal augments have been introduced with, excellent biomechanical characteristics and biocompatibility, allowing early stability and greater bone ingrowth. The aim of the study was to assess the short term clinical and radiological outcome of the trabecular metal augments. MA...

متن کامل

The management of bone loss in revision total knee arthroplasty: rebuild, reinforce, and augment.

The treatment of bone loss in revision total knee arthroplasty has evolved over the past decade. While the management of small to moderate sized defects has demonstrated good results with a variety of traditional techniques (cement and screws, small metal augments, impaction bone grafting or modular stems), the treatment of severe defects continues to be problematic. The use of a structural all...

متن کامل

Impaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute

BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...

متن کامل

Early results of trabecular metal augment for acetabular reconstruction in revision hip arthroplasty.

The management of acetabular bone defects presents a challenge in revision total hip arthroplasty (THA). The aim of this study was to assess the early clinical and radiological outcome of revision of acetabular components using trabecular metal cups and augments for acetabular reconstruction. The study included 18 consecutive patients with failed acetabular components after total hip arthroplas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2012