Using the Internet for image transfer in a regional trauma network: effect on CT repeat rate, cost, and radiation exposure.
نویسندگان
چکیده
PURPOSE The aims of this study were to evaluate an Internet-based and compact disc-based image transfer system and to compare this system with others in the literature, specifically regarding effects on repeat imaging rate, cost, and radiation dose to patients transferred to a level I regional trauma center. METHODS Five hundred consecutive trauma patients transferred to a level I trauma center between June 1 and July 15, 2009, were included in the study. Images were transferred from an outside facility to the trauma center using the Internet and compact discs and uploaded to the trauma center's PACS. Radiographic studies and CT scans at the trauma center were classified as outside studies, completion studies, or repeat studies. Repeat rate, costs, and radiation doses of transferred and repeated CT scans were calculated. RESULTS Four hundred ninety-one patients met the inclusion criteria. The patients' average age was 40.5 years, and 70% were men. The average Injury Severity Score was 14.7. Three hundred eighty-three patients had 852 CT studies and 380 nonextremity radiographs imported into the trauma center's PACS. At the trauma center, 494 completion CT scans and 2,924 radiographic studies were performed on these patients. Sixty-nine repeat CT scans were performed on 55 patients, equalling a 17% repeat rate. The total value of imported CT studies was $244,373.69. Repeat imaging totaled $20,495.95, or $84.65 per patient with transferred CT studies. CONCLUSIONS Using a combination of the Internet and compact discs to transfer images during inter-hospital transfer is associated with much lower repeat rates than those in the literature, suggesting that regional PACS networks may be useful for reducing cost and radiation exposure associated with trauma.
منابع مشابه
Repeat analysis program in radiology departments in Mazandaran province- Iran Impact on population radiation dose
Background: The rejected films in radiography may be responsible for an unnecessary increase in the radiation dose to the population. The effective dose to population is a very important factor in estimation of stochastic risk in radiology. The main goal of this study was to determine the effective dose to members of the public due to rejected films in diagnostic radiology departments in the No...
متن کاملImage Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملProspective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...
متن کاملMedical imaging modalities: Prevention of unnecessary orders and non-optimized radiation exposure
Magnetic resonance imaging (MRI) uses a constant magnetic field and radio waves, a non-invasive method for examining tissues, organs and the skeletal system. Advantages and disadvantages of MRI are not fully understood; however, it has been commonly used in the diagnosis of skeleton and bone diseases (such as disk and spinal disorders, joint disorders (arthritis), bone tumours and tissues...
متن کاملAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study
Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Radiology : JACR
دوره 9 9 شماره
صفحات -
تاریخ انتشار 2012