Altered selectivity of a dipicolylamine based metal ion receptor.
نویسندگان
چکیده
2,2-Dipicolylamine (DPA) based receptors detect Zn(2+) with high fidelity. A fluorescent sensor with thiocarbamate-linked DPA turns it into a highly selective module for Ag(+) with up to ~7-fold enhancement of fluorescence. The sensor exhibits a double ratiometric behavior. It also displays an interesting [Ag(+)] dependent aggregation induced emission.
منابع مشابه
Solvent effect on the fluorescence response of hydroxycoumarin bearing a dipicolylamine binding site to metal ions.
The fluorescence behavior of a probe dpa-HC, which has a coumarin derivative that acts as a fluorophore and a dipicolylamine (DPA) unit that functions as a metal ion-recognition site, was investigated with various metal ions in aqueous and several non-aqueous solvents. In aqueous solution, the fluorescence of dpa-HC was enhanced by Zn(2+) and Cd(2+), but was quenched by other metal ions. On the...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملA mercury(II) ion sensor device based on an organic field effect transistor with an extended-gate modified by dipicolylamine.
Herein, we report an organic field effect transistor (OFET) with an extended-gate modified by an artificial receptor for the detection of mercury(II) ions (Hg(2+)) in water. The sensor device is easy to fabricate, reusable, disposable, and portable. Thus OFET sensors could be applied for low-cost on-site detection of Hg(2+).
متن کاملSupported Liquid Membrane in Metal Ion Separation: An Overview
Using liquid membrane and, in particular, supported liquid membrane (SLM) is a novel method of separation in comparison to other methods such as adsorption, extraction and ion exchange. SLM is a combination of simultaneous extraction and disposal whose high efciency and capability is proven by many studies. So far, many researchers have utilized SLM in various scientifc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chemical communications
دوره 50 1 شماره
صفحات -
تاریخ انتشار 2014