In-situ electric field and current density in Japanese male and female models for uniform magnetic field exposures.
نویسندگان
چکیده
The present study quantified the in situ electric field and induced current density in anatomically based numeric Japanese male and female models for exposure to extremely low-frequency magnetic fields. A quasi-static FDTD method was applied to analyse this problem. The computational results obtained herein reveal that the 99 th percentile value of the in situ electric field in the nerve tissue and the current density averaged over an area of 1 cm(2) of the nerve tissue (excluding non-nerve tissues in the averaging region) in the female models were less than 35 and 25 %, respectively. These induced quantities in the Japanese models were smaller than those for European models reported in a previous study, which is mainly due to the difference in cross-sectional area of the body.
منابع مشابه
Intercomparison of Induced Fields in Japanese Male Model TARO Due to Magnetic Field Exposures
The present study provides an intercomparison of the in-situ electric field and current density in a Japanese adult male model named TARO for uniform magnetic field exposures. Total of six institutes has joined this intercomparison. Except for inhouse computational codes developed at institutes, computational conditions were set identical to focus on the discussion of computational uncertainty....
متن کاملThe modeling of induced current density in eyes from static magnetic fields produce by MR scanner
Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...
متن کاملRapid mixing of Newtonian and non-Newtonian fluids in a three-dimensional micro-mixer using non-uniform magnetic field
The mixing of Newtonian and non-Newtonian fluids in a magnetic micro-mixer was studied numerically using ferrofluid. The mixing process was performed in a three-dimensional steady-state micro-mixer. A magnetic source was mounted at the entrance of the micro-channel to oscillate the magnetic particles. The effects of electric current, inlet velocity, size of magnetic particles, and non-Newtonia...
متن کاملDosimetry in Japanese male and female models for a low-frequency electric field.
The present study quantified induced current in anatomically based Japanese male and female models for exposure to low-frequency electric fields. A quasi-static finite-difference time-domain (FDTD) method was applied to analyze this problem. For our computational results, the difference of the induced current density averaged over an area of 1 cm(2) between Japanese male and female models was l...
متن کاملThree-dimensional calculations of the magnetic fields in a finite superconducting hollow cylinder in an applied axial magnetic field
In this study, a set of self-consistent coupled-integral equations for the local magnetic flux and current distributions in a finite superconducting hollow cylinder under an axial magnetic field has been directly derived by using the Biot-Savart law within the framework of the critical-state model. The equations were first solved numerically in the three-dimensional space before obtaining the h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 135 4 شماره
صفحات -