Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers

نویسندگان

  • Elizabeth M Tunnicliffe
  • Andrew D Scott
  • Pedro Ferreira
  • Rina Ariga
  • Laura-Ann McGill
  • Sonia Nielles-Vallespin
  • Stefan Neubauer
  • Dudley J Pennell
  • Matthew D Robson
  • David N Firmin
چکیده

BACKGROUND Diffusion tensor cardiac magnetic resonance (DT-CMR) enables probing of the microarchitecture of the myocardium, but the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) reported in healthy volunteers have been inconsistent. The aim of this study was to validate a stimulated-echo diffusion sequence using phantoms, and to assess the intercentre reproducibility of in-vivo diffusion measures using the sequence. METHODS AND RESULTS A stimulated-echo, cardiac-gated DT-CMR sequence with a reduced-field-of-view, single-shot EPI readout was used at two centres with 3 T MRI scanners. Four alkane phantoms with known diffusivities were scanned at a single centre using a stimulated echo sequence and a spin-echo Stejskal-Tanner diffusion sequence. The median (maximum, minimum) difference between the DT-CMR sequence and Stejskal-Tanner sequence was 0.01 (0.04, 0.0006) × 10(-3) mm2/s (2%), and between the DT-CMR sequence and literature diffusivities was 0.02 (0.05, 0.006) × 10(-3) mm2/s (4%).The same ten healthy volunteers were scanned using the DT-CMR sequence at the two centres less than seven days apart. Average ADC and FA were calculated in a single mid-ventricular, short axis slice. Intercentre differences were tested for statistical significance at the p < 0.05 level using paired t-tests. The mean ADC ± standard deviation for all subjects averaged over both centres was 1.10 ± 0.06 × 10(-3) mm2/s in systole and 1.20 ± 0.09 × 10-3 mm2/s in diastole; FA was 0.41 ± 0.04 in systole and 0.54 ± 0.03 in diastole. With similarly-drawn regions-of-interest, systolic ADC (difference 0.05 × 10(-3) mm2/s), systolic FA (difference 0.003) and diastolic FA (difference 0.01) were not statistically significantly different between centres (p > 0.05), and only the diastolic ADC showed a statistically significant, but numerically small, difference of 0.07 × 10(-3) mm2/s (p = 0.047). The intercentre, intrasubject coefficients of variance were: systolic ADC 7%, FA 6%; diastolic ADC 7%, FA 3%. CONCLUSIONS This is the first study to demonstrate the accuracy of a stimulated-echo DT-CMR sequence in phantoms, and demonstrates the feasibility of obtaining reproducible ADC and FA in healthy volunteers at separate centres with well-matched sequences and processing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-centre reproducibility of cardiac diffusion tensor measures

Background Diffusion tensor imaging is a technique which, by studying the small motions of water molecules in biological tissue, could provide new insights into the myoarchitecture of both healthy and diseased hearts. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) are values derived from the measured diffusion tensor and which have previously shown some sensitivity to d...

متن کامل

Inter Subject Variability and Reproducibility of Diffusion Tensor Imaging within and between Different Imaging Sessions

The aim of these studies was to provide reference data on intersubject variability and reproducibility of diffusion tensor imaging. Healthy volunteers underwent imaging on two occasions using the same 3T Siemens Verio magnetic resonance scanner. At each session two identical diffusion tensor sequences were obtained along with standard structural imaging. Fractional anisotropy, apparent diffusio...

متن کامل

Reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and 1H magnetic resonance spectroscopy at 3.0 Tesla.

OBJECTIVES The reproducibility of quantitative cerebral T2 relaxometry, diffusion tensor imaging, and H magnetic resonance (MR) spectroscopic imaging was assessed on a clinical 3.0 T MR system. MATERIALS AND METHODS Repeated measurements in 10 healthy volunteers were used to establish the reproducibility of quantitative measures derived from different quantitative MR techniques, namely the T2...

متن کامل

Intercentre reproducibility of second eigenvector orientation in cardiac diffusion tensor imaging

Background Diffusion tensor imaging enables the study of cardiac microstructure in vivo, including its changes through the cardiac cycle. The left ventricle consists of myocytes with opposing helical arrangements in the epiand endocardium. Histology shows that these myocytes are arranged into small laminar “sheetlet” structures, separated by shear layers which allow the sheetlets to move and re...

متن کامل

Bulk motion-independent analyses of water diffusion changes in the brain during the cardiac cycle.

We evaluated dynamic changes in water diffusion in the brain during the cardiac cycle by using cine diffusion MRI. On a 1.5-T MRI, ECG-triggered single-shot diffusion echo planar imaging was used with sensitivity encoding, halfscan, and rectangular field of view techniques for minimizing bulk motion effects such as brain pulsation, with a data-sampling window of 3 ms. The apparent diffusion coe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014