Bilateral C1-C2 claw for atlantoaxial instability.

نویسندگان

  • Hakan Hanimoglu
  • Lale Hanci
  • Mehmet Yasar Kaynar
  • Murat Hanci
چکیده

OBJECTIVE Atlantoaxial stability can be achieved by laminar hook systems via posterior approach. This technique is much more safer than using screws. We presented our experience with the C1-C2 claw procedure. METHODS AND MATERIAL Seven patients with atlantoaxial instability were operated by using C1 and C2 hooks, rods and transverse connector at Neurosurgery Clinic of Istanbul University Cerrahpasa Medical Faculty between the years 2005 and 2008. RESULTS Satisfactory stabilization was achieved in all patients. Operative complication or instrumentation failure was not observed. CONCLUSIONS C1-C2 claw is a safe technique and adequate stabilization is achieved with the use of a transverse connector.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel method of C1–C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block

Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that w...

متن کامل

Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

AIM In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. MATERIAL AND METHODS Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016...

متن کامل

Atlantoaxial Fixation—Anterior or Posterior Approach: Critical Review

Atlantoaxial facet joints have been proposed as the center of mobility and also center for instability of the atlantoaxial region. Because of the high mobility of the atlantoaxial (C1-C2) motion segment, fusion rates at this level have been substantially lower than those at the subaxial spine. The success of craniovertebral junction surgery depends on adequate reduction, decompression of cranio...

متن کامل

Bilateral C1–C2 Transarticular Screw and C1 Laminar Hook Fixation and Bone Graft Fusion for Reducible Atlantoaxial Dislocation: A Seven-Year Analysis of Outcome

BACKGROUND Bilateral C1-2 transarticular screw and C1 laminar hook fixation was developed on the basis of transarticular screws fixation. The modified technique has showed a better biomechanical stability than established techniques in previous study. However, long-term (minimum follow-up 7 years) outcomes of patients with reducible atlantoaxial dislocation who underwent this modified fixation ...

متن کامل

Biomechanical Comparison of Five Different Atlanto-axial Posterior Cervical Fixation

Introduction: Previous investigations have demonstrated that threepoint fixation, using bilateral transarticular screws in combination with posterior wiring, provide the most effective resistance to minimize motion about C1-C2. However, transarticular screws are technically demanding and require considerable experience. Posterior wiring techniques affording one point of fixation, such as Brooks...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 19 4  شماره 

صفحات  -