Integrated measurement of the mass and surface charge of discrete microparticles using a suspended microchannel resonator.
نویسندگان
چکیده
Measurements of the mass and surface charge of microparticles are employed in the characterization of many types of colloidal dispersions. The suspended microchannel resonator (SMR) is capable of measuring individual particle masses with femtogram resolution. Here, we employ the high sensitivity of the SMR resonance frequency to changes in particle position, relative to the cantilever tip, to determine the electrophoretic mobility of discrete particles in an applied electric field. When a sinusoidal electric field is applied to the suspended microchannel, the transient resonance frequency shift corresponding to a particle transit can be analyzed by digital signal processing to extract both the buoyant mass and electrophoretic mobility of each particle. These parameters, together with the mean particle density, can be used to compute the size, absolute mass, and surface charge of discrete microspheres, leading to a true representation of the mean and polydispersity of these quantities for a population. We have applied this technique to an aqueous suspension of two types of polystyrene microspheres, to differentiate them based on their absolute mass and their surface charge. The integrated measurement of electrophoretic mobility using the SMR is determined to be quantitative, based on comparison with commercial instruments, and exhibits favorable scaling properties that will ultimately enable measurements from mammalian cells.
منابع مشابه
Fabrication and Characterization of an Integrated Microsystem for Biomolecular Preconcentration and Sensing
1 We report on a fabrication and packaging process for a microsystem consisting of a mass-based 2 protein detector and a fully integrated preconcentrator. Preconcentration of protein is achieved 3 by means of a nanofluidic concentrator, which takes advantage of fast non-linear electro-osmotic 4 flow near a nanochannel-microchannel junction to concentrate charged molecules inside a 5 volume of f...
متن کاملSuspended microchannel resonators for biomolecular detection
We have demonstrated a new approach for detecting biomolecular mass in the aqueous environment. Known as the suspended microchannel resonator (SMR), target molecules flow through a suspended microchannel and are captured by receptor molecules attached to the interior channel walls [1]. As with other resonant mass sensors, the SMR detects the amount of captured target molecules via the change in...
متن کاملCalculation of the Induced Charge Distribution on the Surface of a Metallic Nanoparticle Due to an Oscillating Dipole Using Discrete Dipole Approximation method
In this paper, the interaction between an oscillating dipole moment and a Silver nanoparticle has been studied. Our calculations are based on Mie scattering theory and discrete dipole approximation(DDA) method.At first, the resonance frequency due to excitingthe localized surface plasmons has been obtained using Mie scattering theory and then by exciting a dipole moment in theclose proximity of...
متن کاملMeasuring single cell mass, volume, and density with dual suspended microchannel resonators.
Cell size, measured as either volume or mass, is a fundamental indicator of cell state. Far more tightly regulated than size is density, the ratio between mass and volume, which can be used to distinguish between cell populations even when volume and mass appear to remain constant. Here we expand upon a previous method for measuring cell density involving a suspended microchannel resonator (SMR...
متن کاملMeasurement of mass, density, and volume during the cell cycle of yeast.
Cell growth comprises changes in both mass and volume--two processes that are distinct, yet coordinated through the cell cycle. Understanding this relationship requires a means for measuring each of the cell's three basic physical parameters: mass, volume, and the ratio of the two, density. The suspended microchannel resonator weighs single cells with a precision in mass of 0.1% for yeast. Here...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 81 11 شماره