Detection of Electrophysiology Catheters in Noisy Fluoroscopy Images

نویسندگان

  • Erik Franken
  • Peter M. J. Rongen
  • Markus van Almsick
  • Bart M. ter Haar Romeny
چکیده

Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noisy images edge detection: Ant colony optimization algorithm

The edges of an image define the image boundary. When the image is noisy, it does not become easy to identify the edges. Therefore, a method requests to be developed that can identify edges clearly in a noisy image. Many methods have been proposed earlier using filters, transforms and wavelets with Ant colony optimization (ACO) that detect edges. We here used ACO for edge detection of noisy ima...

متن کامل

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system.

AIMS Radiofrequency (RF) ablation requires placement of several catheters at critical positions. The catheters are positioned with fluoroscopy, resulting in a significant radiation exposure. We have investigated to what degree an intracardiac navigation system reduces the fluoroscopy duration in different groups of routine RF ablations. METHODS AND RESULTS The fluoroscopy time was evaluated i...

متن کامل

Fluoroscopy-Free Electrophysiology Study Using 3D Electroanatomic Mapping System: A Case Report and Review of Literature

Due to the use of fluoroscopy in the electrophysiology lab, long and complex procedures to diagnose and treat cardiac arrhythmias can lead to radiation exposure to both patients and the laboratory staff. In this report, we present a case in which a diagnostic electrophysiology study was conducted on a 41 year-old patient with atrial tachycardia without the use of fluoroscopy. The diagnostic com...

متن کامل

Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.

Conventional fluoroscopy is the main imaging technology that allows for intracardiac device manipulation in a variety of interventional cardiovascular procedures. Besides the associated x-ray exposure for patients and staff, that technology only provides 2D orientations. Therefore, 3D mapping technologies have been introduced to facilitate spatial orientation within complex cardiac anatomies. E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 9 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2006