Single-incision anterior approach for total hip arthroplasty on an orthopaedic table.

نویسندگان

  • Joel M Matta
  • Cambize Shahrdar
  • Tania Ferguson
چکیده

UNLABELLED Dislocation remains the leading early complication of total hip arthroplasty; surgical approach and implant positioning have been recognized as factors influencing total hip arthroplasty stability. We describe a total hip arthroplasty technique done through a single, tissue sparing anterior approach that allows implantation of the femoral and acetabular components without detaching or sectioning any of the muscles and tendons around the hip joint. A series of 437 consecutive, unselected patients who had 494 primary total hip arthroplasty surgeries done through an anterior approach on an orthopaedic table from September 1996 to September 2004 was reviewed. There were 54 hybrid and 442 uncemented hips in the 437 patients (57 bilateral). The average patient age was 64 years. Radiographic analysis showed an average abduction angle of 42 degrees , with 96% in the range of 35 degrees to 50 degrees abduction. The average cup anteversion was 19 degrees with 93% within the target range of 10 degrees to 25 degrees . Postoperative leg length discrepancy averaged 3 +/- 2 mm (range, 0-26 mm). Three patients sustained dislocations for an overall dislocation rate of 0.61%, and no patients required revision surgery for recurrent dislocation. There were 17 operative complications, including one deep infection, three wound infections, one transient femoral nerve palsy, three greater trochanter fracture, two femoral shaft fractures four calcar fractures, and three ankle fractures. Operative time averaged 75 minutes (range 40-150 minutes), and the average blood loss was 350 mL (range, 100-1300 mL). The mean hospital stay was 3 days (range, 1-17 days). The anterior approach on the orthopaedic table is a minimally invasive technique applicable to all primary hip patients. This technique allows accurate and reproducible component positioning and leg-length restoration and does not increase the rate of hip dislocation. LEVEL OF EVIDENCE Therapeutic study, Level IV-1 (case series). See the Guidelines for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the Fitmore® hip stem bone-preserving system for the minimally invasive anterior-supine approach in hip replacement.

Total hip arthroplasty through a single-incision anterior approach is a minimally invasive surgical (MIS) technique that allows component placement without violation of the posterior hip capsule or "hip deltoid." This allows faster recovery without dislocation precautions. The Fitmore® hip stem (Zimmer, Warsaw, Ind) is a bone-conserving stem designed for use in MIS techniques. The technique des...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Surgical approaches to total hip arthroplasty.

Surgical exposure of the hip for trauma, infection, or reconstruction can be adequately accomplished through a variety of surgical approaches. This article describes in detail five classic approaches to the hip: Smith-Petersen (anterior), Watson-Jones (anterolateral), Hardinge (direct lateral), transtrochanteric, and posterolateral. In addition, recently described mini-incision posterior and an...

متن کامل

[Surgical approaches in total hip arthroplasty].

Modern advances in total hip arthroplasty have included improved biomaterials, alternative bearings, so-called fourthgeneration cement techniques, and enhanced in-growth prostheses. Recently, much attention has been focused on improving the surgical technique for total hip arthroplasty. This endeavor has included the development of mini-incision arthroplasty and has now progressed to minimally ...

متن کامل

Safe surgical technique: iliac osteotomy via the anterior approach for revision hip arthroplasty

Robert Judet first performed hip arthroplasty via the anterior approach (AA) in 1947 on an orthopaedic table. Our center has a near 20-year experience on more than 3500 patients operated by AA hip arthroplasty. While primary AA total hip arthroplasty techniques have been discussed in the literature, revision AA total hip arthroplasty techniques are relatively new. The current article in the Jou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 441  شماره 

صفحات  -

تاریخ انتشار 2005