Functional Results after Repair of Large Hiatal Hernia by Use of a Biologic Mesh
نویسندگان
چکیده
BACKGROUND The aim of this observational study is to analyze the results of patients with large hiatal hernia and upside-down stomach after surgical closure with a biological mesh (Permacol(®), Covidien, Neustadt an der Donau, Germany). Biological mesh is used to prevent long-term detrimental effects of artificial meshes and to reduce recurrence rates. METHODS A total of 13 patients with a large hiatal hernia and endothoracic stomach, who underwent surgery between 2010 and 2014, were included. Interviews and upper endoscopy were conducted to determine recurrences, lifestyle restrictions, and current complaints. RESULTS After a mean follow-up of 26 ± 18 months (range: 3-58 months), 10 patients (3 men, mean age 73 ± 13, range: 26-81 years) were evaluated. A small recurrent axial hernia was found in one patient postoperatively. Dysphagia was the most common complaint (four cases); while in one case, the problem was solved after endoscopic dilatation. In three cases, bloat and postprandial pain were documented. In one case, an explantation of the mesh was necessary due to mesh migration and painful adhesions. In one further case with gastroparesis, pyloroplasty was performed without success. The data are compared to the available literature. It was found that dysphagia and recurrence rates are unrelated both in biological and in synthetic meshes if the esophagus is encircled. In series preserving the esophagus at least partially uncoated, recurrences after the use of biological meshes relieve dysphagia. After the application of synthetic meshes, dysphagia is aggravated by recurrences. CONCLUSION Recurrence is rare after encircling hiatal hernia repair with the biological mesh Permacol(®). Dysphagia, gas bloat, and intra-abdominal pain are frequent complaints. Despite the small number of patients, it can be concluded that a biological mesh may be an alternative to synthetic meshes to reduce recurrences at least for up to 2 years. Our study demonstrates that local fibrosis and thickening of the mesh can affect the outcome being associated with abdominal discomfort despite a successful repair. The review of the literature indicates comparable results after 2 years with both biologic and synthetic meshes embracing the esophagus. At the same point in time, reconstruction with synthetic and biologic materials differs when the esophagus is not or only partially encircled in the repair. This is important since encircling artificial meshes can erode the esophagus after 5-10 years.
منابع مشابه
Surgical Repair of Giant Type IV Hiatal Hernia
In this case report, we described a 74-year-old female patient with major complaint of respiratory problemsdyspnea after meal. Chest X-ray of the patient revealed a gianttype IV hiatal hernia. Preoperative evaluations of the patient included esophagoscopy, esophageal manometry, barium swallow, and CT-scan. Repair of the hernia was performed using a dual mesh on the diaphragm and partial anteri...
متن کاملBiologic Keyhole Mesh in Hiatal Hernia Repair
Background and Objectives Laparoscopic paraesophageal hernia repair (LPEHR) is the new standard, but the use of mesh is still debated. Biologic mesh has shown great promise, but only the U-shaped onlay has been extensively studied. Postoperative dysphagia has historically been a concern with the use of synthetic keyhole mesh and subsequently slowed its adoption. The purpose of our study was to ...
متن کاملThe Use of Biological Meshes in Diaphragmatic Defects – An Evidence-Based Review of the Literature
The widespread use of meshes for hiatal hernia repair has emerged in the era of laparoscopic surgery, although sporadic cases of mesh augmentation of traumatic diaphragmatic rupture have been reported. The indications for biologic meshes in diaphragmatic repair are ill defined. This systematic review aims to investigate the available evidence on the role of biologic meshes in diaphragmatic rupt...
متن کاملLaparoscopic Hiatal Hernia Repair in 221 Patients: Outcomes and Experience.
BACKGROUND AND OBJECTIVES Hiatal hernia is a common condition often associated with symptomatic gastroesophageal reflux disease (GERD). The objectives of this study were to examine the efficacy and safety of laparoscopic hiatal hernia repair (LHHR) with biologic mesh to reduce and/or alleviate GERD symptoms and associated hiatal hernia recurrence. METHODS We retrospectively reviewed consecuti...
متن کاملProsthetic Bioabsorbable Mesh for Hiatal Hernia Repair During Sleeve Gastrectomy
BACKGROUND AND OBJECTIVES Laparoscopic sleeve gastrectomy has become a valuable primary bariatric operation. It has an acceptable complication profile and amount of weight loss. However, one of the most distressing complications to the patient is reflux postoperatively. There is thought to be a relationship between a hiatal hernia and postoperative reflux. There is disagreement on how to addres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2016