Influence of ageing treatment on the thermophysical characteristics and mechanical properties of forging wire Ni-rich NiTi alloy for superelastic applications

نویسندگان

  • P. F. Rodrigues
  • F.M.B. Fernandes
  • E. N. Texeira
  • S. Baptista
  • A. S. Paula
  • J. P. Oliveira
چکیده

NiTi alloys used for orthodontic applications need to show superelastic characteristics at room and oral temperatures. The ideal scenario is that where the material has a final austenitic phase transformation value below the room temperature. This study aims at understanding the influence of the ageing treatments in the austenitic structure at room temperature on a wire of a Ni-rich NiTi alloy produced by rotary forging by the evaluation of the phase transformation temperatures and mechanical behaviour in order to promote the superelastic behaviour at room temperature. The investigation was conducted using DSC (Differential Scanning Calorimetry) analysis and instrumented ultramicrohardness. The solubilisation at 950°C for 120 min with water quenching showed a satisfactory amount of B2 phase at room temperature when compared to the sample after forging. After solubilisation, ageing treatment at 350°C for 30 min gave a relatively higher hardness value and an Af temperature below the room temperature, ensuring the presence of austenitic phase at room and oral temperatures. © 2017 Portuguese Society of Materials (SPM). Published by Elsevier España, S.L.U.. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performing a Calcium-Phosphate Layer on Porous NiTi Alloy for Using in Orthopedic Applications

Porous NiTi alloys has a series of unique properties such as shape memory effect, superelastic behavior and energy absorbability that make them usable in a wide range of medical and industrial appliances. But the more probability of Ni release from a porous NiTi compare to the nonporous one has restricted it’s uses in implants. In the present research for resolving the problem, performing a cal...

متن کامل

Performing a Calcium-Phosphate Layer on Porous NiTi Alloy for Using in Orthopedic Applications

Porous NiTi alloys has a series of unique properties such as shape memory effect, superelastic behavior and energy absorbability that make them usable in a wide range of medical and industrial appliances. But the more probability of Ni release from a porous NiTi compare to the nonporous one has restricted it’s uses in implants. In the present research for resolving the problem, performing a cal...

متن کامل

Fabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel

Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...

متن کامل

Combined effects of different heat treatments and Cu element on transformation behavior of NiTi orthodontic wires.

The shape memory nickel-titanium alloy has been applied in many fields due to its unique thermal and mechanical performance. One of the successful applications of NiTi wires is in orthodontics because of its good characteristics such as low stiffness, high spring back, high stored energy, biocompatibility, superelasticity and shape memory effect. The mechanical properties of wires are paid spec...

متن کامل

Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatment. Part 2: Microscopic surface appraisal and metallurgical characteristics

OBJECTIVE This research aimed at comparing the qualitative chemical compositions and the surface morphology of fracture regions of eight types of Nickel/Titanium (NiTi) conventional wires, superelastic and heat-activated (GAC, TP, Ormco, Masel, Morelli and Unitek), to the wires with addition of copper (CuNiTi 27ºC and 35ºC, Ormco) after traction test. METHODS The analyses were performed in a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017