Characterization and use of a Raman liquid-core waveguide sensor using preconcentration principles.

نویسندگان

  • Sumalee Tanikkul
  • Jaroon Jakmunee
  • Mongkon Rayanakorn
  • Kate Grudpan
  • Brian J Marquardt
  • Gwen M Gross
  • Bryan J Prazen
  • Lloyd W Burgess
  • Gary D Christian
  • Robert E Synovec
چکیده

A novel Raman sensor using a liquid-core optical waveguide is reported, implementing a Teflon-AF 2400 tube filled with water. An aqueous analyte mixture of benzene, toluene and p-xylene was introduced using a 1000 microl sample loop to the liquid-core waveguide (LCW) sensor and the analytes were preconcentrated on the inside surface of the waveguide tubing. The analytes were then eluted from the waveguide using an acetonitrile-water solvent mixture injected via a 30 microl eluting solvent loop. The preconcentration factor was experimentally determined to be 14-fold, in reasonable agreement with the theoretical preconcentration factor of 33 based upon the sample volume to elution volume ratio. Raman spectra of benzene, toluene and p-xylene were obtained during elution. It was found that analytically useful Raman signals for benzene, toluene and p-xylene were obtained at 992, 1004 and 1206 cm(-1), respectively. The relative standard deviation of the method was 3% for three replicate measurements. The limit of detection (LOD) was determined to be 730 ppb (parts per billion by volume) for benzene, exceptional for a system that does not resort to surface enhancement or resonance Raman approaches. The Raman spectra of these test analytes were evaluated for qualitative and quantitative analysis utility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design

In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...

متن کامل

Quantitative analysis of Raman signal enhancement from aqueous samples in liquid core optical fibers.

Raman scattering from aqueous liquids can be collected with high efficiency by enclosing the liquid within a suitable waveguide, as several groups have reported. Here, we present a quantitative model that predicts the relative strength of signals collected from (a) a tubular waveguide and (b) a flat-walled cuvette. Experimental measurements of Raman scattering from aqueous ethanol are made usin...

متن کامل

Improvement the reflection coefficient of Waveguide-Fed Phased-Array Antenna utilizing Liquid Crystal

Abstract— This work investigates the improvement of the active reflection coefficient of waveguide-fed phased-array antenna using liquid crystal layers. The anisotropy properties of liquid crystal layer can be employed to eliminate blind scan angle and improve the wide angle impedance matching of the waveguide-fed phased array antennas. The authors have expressed the modal analysis of the waveg...

متن کامل

Fabrication and Characterization of the Fiber Optical Taper for a Surface Plasmon Resonance Sensor

For a fiber optical surface plasmon resonance (SPR) sensor a short part of its cladding should be removed to coat a thin layer of a metal. Usually this is problematic when an optical fiber with small core diameter is used. In this paper, a new method using µliter droplet of the HF acid for short fiber optical taper fabrication is reported. Using this method in a multi-mode optical fiber w...

متن کامل

In-situ preconcentration, and electrochemical sensing of Zinc(II) and Copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane divided into pieces of 2 cm, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 2003