High-Q Fabry–Pérot Micro-Cavities for High-Sensitivity Volume Refractometry
نویسندگان
چکیده
This work reports a novel structure for a Fabry–Pérot micro cavity that combines the highest reported quality factor for an on-chip Fabry–Pérot resonator that exceeds 9800, and a very high sensitivity for an on-chip volume refractometer based on a Fabry–Pérot cavity that is about 1000 nm/refractive index unit (RIU). The structure consists of two cylindrical Bragg micromirrors that achieve confinement of the Gaussian beam in the plan parallel to the chip substrate, while for the perpendicular plan, external fiber rod lenses (FRLs) are placed in the optical path of the input and the output of the cavity. This novel structure overcomes number of the drawbacks presented in previous designs. The analyte is passed between the mirrors, enabling its detection from the resonance peak wavelengths of the transmission spectra. Mixtures of ethanol and deionized (DI)-water with different ratios are used as analytes with different refractive indices to exploit the device as a micro-opto-fluidic refractometer. The design criteria are detailed and the modeling is based on Gaussian-optics equations, which depicts a scenario closer to reality than the usually used ray-optics modeling.
منابع مشابه
Optofluidic Fabry-Pérot Micro-Cavities Comprising Curved Surfaces for Homogeneous Liquid Refractometry - Design, Simulation, and Experimental Performance Assessment
In the scope of miniaturized optical sensors for liquid refractometry, this work details the design, numerical simulation, and experimental characterization of a Fabry-Pérot resonator consisting of two deeply-etched silicon cylindrical mirrors with a micro-tube in between holding the liquid analyte under study. The curved surfaces of the tube and the cylindrical mirrors provide three-dimensiona...
متن کاملHigh-sensitivity measurements of the Kerr constant in gases using a Fabry–Pérot-based ellipsometer
The dc-Kerr constant was measured with high sensitivity in several gases, using a novel ellipsometer, which is based on a high-finesse Fabry–Pérot interferometer. An effective interaction length of 5.26 km was achieved by using a Fabry–Pérot interferometer with intracavity electrodes, yielding a single-pass sensitivity of ≈ 10 nanoradian. The dc-Kerr constants of CO2, N2, and O2 were determined...
متن کاملMicro-air-gap based intrinsic Fabry-Perot interferometric fiber-optic sensor.
A simple intrinsic Fabry-Perot interferometric (IFPI) sensor is developed. The sensor is fabricated by two micro air gaps as reflective mirrors in a fiber to form a Fabry-Perot cavity. Theoretical and experimental studies of the sensor are described. Experimental results show that high resolution and high sensitivity can be achieved. Two structures of micro-air-gap-based IFPI sensors offer more...
متن کاملGaN/air gap based micro-opto-electro-mechanical (MOEM) Fabry-Pérot filters
E. Cho *, 1, 2 , D. Pavlidis **, 1, 2 , and E. Sillero 1 Department of High Frequency Electronics, Technische Universität Darmstadt, Merckstrasse 25, 64283 Darmstadt, Germany 2 Department of Electrical Engineering and Computer Science, The University of Michigan, Ann Arbor, MI 48109-2122, USA 3 Instituto de Sistemas Optoelectrónicos y Microtecnología and Department of Electronic Engineering, Un...
متن کاملAn optical vernier technique for in situ measurement of the length of long Fabry–Pérot cavities
We propose a method for in situ measurement of the length of kilometre-sized Fabry–Pérot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser beam incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From...