A comparative assessment of forces and moments generated by lingual and conventional brackets.

نویسندگان

  • Iosif Sifakakis
  • Nikolaos Pandis
  • Margarita Makou
  • Christos Katsaros
  • Theodore Eliades
  • Christoph Bourauel
چکیده

The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative assessment of torque generated by lingual and conventional brackets.

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models ...

متن کامل

Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets.

The objectives of this study were to comparatively assess the magnitude and direction of forces and moments generated from different bracket systems, during the initial levelling and alignment stage of orthodontic treatment. Three types of brackets were used: Orthos2 (Ormco), Damon2 (Ormco), and In-Ovation R (GAC). The brackets were bonded on resin replicas models of a patient's crowded mandibu...

متن کامل

Frictional resistance exerted by different lingual and labial brackets: an in vitro study

BACKGROUND Although much has been written on the implications of friction generated between orthodontic archwires and labial brackets, information on lingual brackets is still limited. Hence, we set out to investigate the frictional resistance exerted by different lingual and labial brackets, including both conventional and self-ligating designs. The effect of various factors, namely bracket/ba...

متن کامل

Effect of Ligation Method on Maxillary Arch Force/Moment Systems for a Simulated Lingual Incisor Malalignment

INTRODUCTION The objectives of this study were to determine whether there is a difference in the magnitude of forces and moments produced by elastic ligation when compared to passive ligation, and whether these forces and moments propagate differently along the arch for the two ligation types. A lingual incisor malalignment was used in this study. METHODS The Orthodontic Simulator (OSIM) was ...

متن کامل

A comparative in vitro study of frictional resistance between lingual brackets and stainless steel archwires.

Friction between archwires and labial brackets has received considerable attention; however, information on the frictional behaviour of commercially available lingual brackets is limited. The aim of this study was to investigate the frictional resistance resulting from a combination of lingual orthodontic brackets (7th Generation, STb, Magic, and In-Ovation L) and stainless steel archwires at 0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of orthodontics

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2013