Ion mobility spectrometer with radial collisional focusing.
نویسندگان
چکیده
An ion mobility spectrometer that has its mobility cell as a 20-segment quadrupole and functionally the q2 of a triple-quadrupole mass spectrometer has been assembled and tested. The combination of high cell pressure (maximum of 4 Torr of helium) and low axial field (20-160 V per 20.2 cm) results in negligible internal excitation of the ions despite applications of rf and axial fields. The presence of collisional focusing ensures efficient ion transmission and good sensitivity. Collision cross sections of atomic, cluster, peptide, and protein ions were measured and found comparable to literature and calculated cross sections.
منابع مشابه
Combined ion-mobility and mass-spectrometry investigations of metallothionein complexes using a tandem mass spectrometer with a segmented second quadrupole.
Rabbit metallothionein (MT) 2A complexes with Cd(II), Zn(II), Ag(I), Cu(I), Hg(II), arsenite, monomethylarsonous acid (MMA), and dimethylarsinous acid (DMA) have been examined using ion-mobility measurements and mass spectrometry in a triple-quadrupole mass spectrometer equipped with a segmented second quadrupole that doubled as an ion-mobility cell [Guo, Y.; Wang, J.; Javahery, G.; Thomson, B....
متن کاملIon mobility-mass spectrometer interface for collisional activation of mobility separated ions.
An ion mobility-mass spectrometer (IM-MS) interface is described that can be employed to perform collisional activation and/or collision-induced dissociation (CID) with good transmission of mobility separated ions to the MS analyzer. The IM-MS interface consists of a stacked-ring ion guide design, where the field strength and pressure ratio can be operated such that structural rearrangement rea...
متن کاملIon mobility-mass spectrometry with a radial opposed migration ion and aerosol classifier (ROMIAC).
The first application of a novel differential mobility analyzer, the radial opposed migration ion and aerosol classifier (ROMIAC), is demonstrated. The ROMIAC uses antiparallel forces from an electric field and a cross-flow gas to both scan ion mobilities and continuously transmit target mobility ions with 100% duty cycle. In the ROMIAC, diffusive losses are minimized, and resolution of ions, w...
متن کاملIon dynamics in a trapped ion mobility spectrometer.
In the present paper, theoretical simulations and experimental observations are used to describe the ion dynamics in a trapped ion mobility spectrometer. In particular, the ion motion, ion transmission and mobility separation are discussed as a function of the bath gas velocity, radial confinement, analysis time and speed. Mobility analysis and calibration procedure are reported for the case of...
متن کاملCoupling ion mobility separations, collisional activation techniques, and multiple stages of MS for analysis of complex peptide mixtures.
An ion trap/ion mobility/quadrupole/collision cell/time-of-flight mass spectrometer that incorporates a differentially pumped orifice-skimmer cone region at the back of the drift tube has been developed for the analysis of peptide mixtures. The combined approach allows a variety of strategies to be employed for collisionally activating ions, and fragments can be monitored by subsequent stages o...