Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation
نویسندگان
چکیده
A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection has been developed and validated for quantification of naringin (NAR) in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm) column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v) as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1). The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV) less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity.
منابع مشابه
High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma
The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...
متن کاملHigh Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma
The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملDevelopment and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma
Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, ...
متن کاملDevelopment and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples
Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2014 شماره
صفحات -