Comparison of predictions made by the intraocular lens master and ultrasound biometry.

نویسندگان

  • Anand B Bhatt
  • Amy C Schefler
  • William J Feuer
  • Sonia H Yoo
  • Timothy G Murray
چکیده

OBJECTIVE To ascertain whether a new instrument that uses partial coherence interferometry technology (Intraocular Lens Master [IOLm]) or ultrasound biometry provides a more accurate prediction of refractive outcomes in cataract surgery. METHODS This was a retrospective medical record review of 421 eyes of 304 patients who underwent cataract surgery with the IOLm and ultrasound biometry from January 3, 2002, to December 2, 2005. The mean difference between the prediction with each technology and the final spherical equivalent was compared. Circumstances in which both technologies failed to make accurate predictions were investigated. RESULTS The mean (SD) of the difference between predicted refraction and final spherical equivalent was -0.43 (0.84) diopters (D) for the IOLm and -0.60 (0.87) D for ultrasound biometry, indicating that on average the IOLm was a closer predictor than ultrasound biometry of the final spherical equivalent (P < .001). The IOLm had a 5% higher likelihood of predicting a spherical equivalent within 0.25 D than ultrasound biometry (P = .06), an 8% higher likelihood of predicting a spherical equivalent within 0.50 D (P < .001), and an 8% higher likelihood of predicting a spherical equivalent within 1.00 D (P < .001). CONCLUSIONS To our knowledge, this is the most eyes examined for cataract surgery in a prospective fashion with both the IOLm and ultrasound biometry. The IOLm is a better predictor of postoperative refraction than ultrasound biometry, particularly within close ranges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.

PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...

متن کامل

Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

مقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت

Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...

متن کامل

SCIENTIFIC REPORT IOLMaster biometry: refractive results of 100 consecutive cases

Aims: To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. Methods: The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 126 7  شماره 

صفحات  -

تاریخ انتشار 2008