Contrast-Based 3D/2D Registration of the Left Atrium: Fast versus Consistent

نویسندگان

  • Matthias Hoffmann
  • Christopher Kowalewski
  • Andreas K. Maier
  • Klaus Kurzidim
  • Norbert Strobel
  • Joachim Hornegger
چکیده

For augmented fluoroscopy during cardiac ablation, a preoperatively acquired 3D model of a patient's left atrium (LA) can be registered to X-ray images recorded during a contrast agent (CA) injection. An automatic registration method that works also for small amounts of CA is desired. We propose two similarity measures: The first focuses on edges of the patient anatomy. The second computes a contrast agent distribution estimate (CADE) inside the 3D model and rates its consistency with the CA as seen in biplane fluoroscopic images. Moreover, temporal filtering on the obtained registration results of a sequence is applied using a Markov chain framework. Evaluation was performed on 11 well-contrasted clinical angiographic sequences and 10 additional sequences with less CA. For well-contrasted sequences, the error for all 73 frames was 7.9 ± 6.3 mm and it dropped to 4.6 ± 4.0 mm when registering to an automatically selected, well enhanced frame in each sequence. Temporal filtering reduced the error for all frames from 7.9 ± 6.3 mm to 5.7 ± 4.6 mm. The error was typically higher if less CA was used. A combination of both similarity measures outperforms a previously proposed similarity measure. The mean accuracy for well contrasted sequences is in the range of other proposed manual registration methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Respiratory motion compensation by model-based catheter tracking during EP procedures

In many cases, radio-frequency catheter ablation of the pulmonary veins attached to the left atrium still involves fluoroscopic image guidance. Two-dimensional X-ray navigation may also take advantage of overlay images derived from static pre-operative 3D volumetric data to add anatomical details otherwise not visible under X-ray. Unfortunately, respiratory motion may impair the utility of stat...

متن کامل

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

'Coumadin ridge' in the left atrium demonstrated on three dimensional transthoracic echocardiography.

An echogenic band like structure was seen in the left atrium on two dimensional transthoracic echocardiography (2D TTE). Full volume three dimensional (3D) TTE and colour Doppler established the surrounding anatomical landmarks, and demonstrated the absence of obstruction related to this band. 3D TTE confirmed that this band like structure was consistent with the ridge between the left atrial a...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016