SOBRA - Shielding Optimization for BRAchytherapy
نویسندگان
چکیده
In this paper, we study a combinatorial problem arising in the development of innovative treatment strategies and equipment using tunable shields in internal radiotherapy. From an algorithmic point of view, this problem is related to circular integer word decomposition into circular binary words under constraints. We consider several variants of the problem, depending on constraints and parameters and present exact algorithms, polynomial time approximation algorithms and NP-hardness results.
منابع مشابه
The effect of central shielding in the dose reporting for cervical cancer in EQD2 era
PURPOSE To evaluate the cumulative dose at point A for three and four centimeters central shielding. MATERIAL AND METHODS The plans of external beam radiotherapy plus conventional intracavitary brachytherapy were performed. Three or four centimeters central shieldings (after 44 Gy) were applied to the standard whole pelvis irradiation. Additional intracavitary brachytherapy 4 × 7 Gy at point ...
متن کاملEvaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code
Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a sing...
متن کاملSimulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources
Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...
متن کاملRadiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding.
To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incid...
متن کاملUsing PSO algorithm optimization for planning 103Pd seeds brachytherapy positions
Radiation therapy, is one of the treatments for cancer. Brachytherapy is a radiotherapeutic technique that a sealed radiation source is placed inside or next to the tissue and has become a mainstream treatment option for cancer. Achieving maximum dose to the gland as well as minimum injury to the adjacent tissues is a basic principle in radiation therapy. Sources configuration must be designed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -