An Image-based Inexpensive 3D Scanner
نویسندگان
چکیده
An image-based model reconstruction system is described in this paper where real images of a rigid object acquired under a simple but controlled environment are used to recover its three dimensional geometry and its surface texture. Based on a multi-image calibration method, an algorithm to extract the rotation axis of a turn-table has been developed. Furthermore, this algorithm can be extended to estimate robustly the initial bounding volume of the object to be modeled. The coarse volume obtained is then carved using a stereo correction method which removes the disadvantages of silhouette-based reconstruction by photoconsistency. The concept of surface particles is adapted in order to extract a texture map for the model. Some existing metrics are used to measure the quality of the reconstructed models.
منابع مشابه
Designing and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملComparison of Image Generation And Processing Techniques For 3D Reconstruction of The Human Skull
The purpose of our study was to compare the accuracy of an unconventional, non-invasive and relatively inexpensive Microscribe (3D digitizer) with a standard widely used and expensive CT-Scan and/or MRI for 3D reconstruction of a human skull, which will be used for biomechanics studies. Two models of the human skull were developed (reconstructed), one using the 3D coordinates generated by the M...
متن کاملExtraction and 3D Segmentation of Tumors-Based Unsupervised Clustering Techniques in Medical Images
Introduction The diagnosis and separation of cancerous tumors in medical images require accuracy, experience, and time, and it has always posed itself as a major challenge to the radiologists and physicians. Materials and Methods We Received 290 medical images composed of 120 mammographic images, LJPEG format, scanned in gray-scale with 50 microns size, 110 MRI images including of T1-Wighted, T...
متن کاملThe Design of an Inexpensive Very High Resolution Scan Camera System
We describe a system for transforming an off-the-shelf flatbed scanner into a $200 scan backend for large format cameras. While we describe both software and hardware aspects, the focus of the paper is on software issues such as color calibration and removal of scanner artifacts. With current scanner technology, the resulting camera system is capable of taking black&white, color, or near-infrar...
متن کاملScanners for Analytic Print Measurement – the devil in the details
Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address charact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Int. J. Image Graphics
دوره 3 شماره
صفحات -
تاریخ انتشار 2003