Hip-inspired implant for revision of failed reverse shoulder arthroplasty with severe glenoid bone loss

نویسندگان

  • Ofir Uri
  • Ian Bayley
  • Simon Lambert
چکیده

BACKGROUND AND PURPOSE Glenoid reconstruction and inverted glenoid re-implantation is strongly advocated in revisions of failed reverse shoulder arthroplasty (RSA). Nevertheless, severe glenoid deficiency may preclude glenoid reconstruction and may dictate less favorable solutions, such as conversion to hemiarthropasty or resection arthropasty. The CAD/CAM shoulder (Stanmore Implants, Elstree, UK), a hip arthroplasty-inspired implant, may facilitate glenoid component fixation in these challenging revisions where glenoid reconstruction is not feasible. We questioned (1) whether revision arthroplasty with the CAD/CAM shoulder would alleviate pain and improve shoulder function in patients with failed RSA, not amenable to glenoid reconstruction, (2) whether the CAD/CAM hip-inspired glenoid shell would enable secure and durable glenoid component fixation in these challenging revisions. PATIENTS AND METHODS 11 patients with failed RSAs and unreconstructable glenoids underwent revision with the CAD/CAM shoulder and were followed-up for mean 35 (28-42) months. Clinical outcomes included the Oxford shoulder score, subjective shoulder value, pain rating, physical examination, and shoulder radiographs. RESULTS The average Oxford shoulder score and subjective shoulder value improved statistically significantly after the revision from 50 to 33 points and from 17% to 48% respectively. Pain rating at rest and during activity improved significantly from 5.3 to 2.3 and from 8.1 to 3.8 respectively. Active forward flexion increased from 25 to 54 degrees and external rotation increased from 9 to 21 degrees. 4 patients required reoperation for postoperative complications. No cases of glenoid loosening occurred. INTERPRETATION The CAD/CAM shoulder offers an alternative solution for the treatment of failed RSA that is not amenable to glenoid reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Glenoid bone loss in primary total shoulder arthroplasty: evaluation and management.

Glenohumeral osteoarthritis is the most common reason for shoulder replacement. Total shoulder arthroplasty provides reliable pain relief and restoration of function, with implant survivorship reported at 85% at 15 years. Glenoid component wear and aseptic loosening are among the most common reasons for revision. Glenoid wear characteristics have been correlated with, among other things, the de...

متن کامل

Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty.

HYPOTHESIS Analyses of polyethylene components retrieved at revision of total knee, hip, and shoulder replacements have been used to study the effect of design, patient, and surgical factors on initial implant performance, but no studies have reported similar types of findings in retrieved humeral polyethylene components in reverse total shoulder arthroplasty. Our hypothesis is that while the c...

متن کامل

Revision of the loose glenoid component in anatomic total shoulder arthroplasty.

Loosening of the glenoid component is a frequent cause of failure of total shoulder arthroplasty (TSA). The etiology of glenoid component loosening is multifactorial and includes aseptic osteolysis, rotator cuff insufficiency, soft tissue instability, and infection. A loose glenoid component is frequently associated with a substantial loss of glenoid bone, which necessitates additional procedur...

متن کامل

Observations on retrieved glenoid components from total shoulder arthroplasty.

HYPOTHESIS Polyethylene components retrieved at revision of total knee and hip replacements have been analyzed to study the effect of design, patient, and surgical factors on initial implant performance, but few studies have reported similar types of findings in retrieved glenoids. MATERIALS AND METHODS From 1979 to 2006, 78 glenoid components were retrieved from revision surgery in 73 patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014