The demystification of magnetic resonance imaging?

نویسنده

  • Rainer Hoffmann
چکیده

The interobserver variability in test interpretation is a key parameter to evaluate the diagnostic reliability of a diagnostic examination. It has been evaluated for most clinically relevant cardiac imaging modalities. In many instances the results have been rather sobering. A considerable variability in the visual assessment of coronary artery stenosis severity has been shown between different readers of coronary angiograms. A high reader disagreement has been shown for interpretation of dobutamine stress echocardiograms. The high variability in the interpretation of dobutamine stress echocardiograms has become a matter of debate and has been used as an argument to doubt the diagnostic competence of the method. Low image quality, a large variability in test performance, and insufficient standardization in image interpretation without any objective parameter to define the test result has been referred to as the major limitations of stress echocardiography. Lower observer variability due to more standardized image acquisition, better image quality, and objective parameters of test interpretation has been shown for perfusion scintigraphy and has been used as an argument for its favourable diagnostic performance. Regarding stress echocardiography, multiple shortcomings could be reduced over time. Image quality could be improved. Along with digital image acquisition and more standardized interpretation criteria refinements in the stress echocardiographic techniques have resulted in higher interobserver agreement. Still, interobserver agreement remained far from optimal. Dobutamine stress cardiovascular magnetic resonance imaging (DSMR) incorporates multiple advantages when compared with stress echocardiography. It is performed using standardized acquisition protocols. The acquired imaging views as well as quality of images is less dependent on the individual sonographers performance and the image quality is excellent in most cases. Thus, interobserver agreement is expected to be high considering the most obvious limitations of dobutamine stress echocardiography. However, data on interobserver agreement in the interpretation of DSMR were sparse until recently. In this issue of the Journal, Paesch et al. report on the interobserver variability in the interpretation of DSMR evaluated in a multicenter setting. The study confirms an excellent image quality in the majority of imaging views with the use of DSMR as reported earlier by the investigators as well as other authors. The study confirms also a high diagnostic accuracy for detection of coronary artery disease for all four readers using this technique. However, while the accuracy was almost similar among the four readers, sensitivity for detection of CAD ranged from as low as 71% to as high as 86%, and the specificity had a discordant trend indicating already that readers vary in their interpretation of image data. The surprise of this study is the relatively low interobserver agreement between the four expert observers from different institutions. The disagreement between the four readers was equally distributed and not the effect of one reader with significant deviations from the other readers. How do we explain this result? Excellent images were thought to ensure high diagnostic accuracy but also to facilitate consistent interpretation because of a high confidence in the perception and interpretation of images. Impaired echocardiographic image quality has been a major cause of lower diagnostic accuracy when comparing dobutamine stress echocardiography with dobutamine stress MRI. Poor imaging conditions with resulting insecurity on the interpretation of images have also been shown to be a major cause of disagreement when analysing stress echocardiograms. The rather disappointing level of interobserver agreement confirms other recently published studies which have also indicated that use of MRI is no warranty to reach nearly perfect agreement between different readers on analysis of regional left ventricular function. The interobserver agreement was on a level previously reported for dobutamine echocardiography applied with most advanced echocardiographic techniques. Given these results it appears that reader agreement may be method and imagequality dependent on a low level of agreement. However, once a relatively high image quality is reached this aspect looses importance and other aspects come into play. Thus, we do not reach almost perfect reader agreement based on excellent image quality alone. The difficulty of divergent test results relates to a different issue, involving in particular, the final pathway of image interpretation, which remains a subjective process based on the individual perception. Analysis of regional systolic

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period

To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...

متن کامل

A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite

Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 2006