Significance of Venous Graft Diameter and Length for Peripheral By-pass Patency
نویسندگان
چکیده
http://www.journal-imab-bg.org / J of IMAB. 2013, vol. 19, issue 1 / ABSTRACT: Objective: To analyze the one-year-patency of infrainguinal arterial reconstructions in relation to venous graft diameter and length . Material and Methods: 56 patent and failed infrainguinal autovenous by-pass reconstructions were followed up for no less than a year. The diameter of the vein was measured at the site of distal anastomosis, and the length after the completion of reconstruction. Results: Results are worse in venous grafts with diameter less than 3.5 mm and length over 40 cm, but the difference between failed and patent by-passes with diameter over 3.5 mm and bigger length is also significant. Shorter and with diameter over 3.5 mm by-passes have the higher percentage patency. Conclusion: Shorter grafts with diameter above 3.5 mm do not guarantee longer patency if distal anastomosis is constructed above diseased run-off segment.
منابع مشابه
Clinical Significance of Venous Graft Size and Run-Off Segment for Peripheral Bypass Patency
Aim: To analyze the one-year-patency of infrainguinal arterial reconstructions in relation to venous graft diameter and length and the run-off segment, when arteries above the proximal anastomosis of the reconstruction are not diseased. Material and Methods: We compared retrospectively for two-year period the diameter, the length of the used vein and the run-off segment in 107 consecutively con...
متن کاملSurgical infrainguinal revascularization for peripheral arterial disease: factors affecting patency rate
Background: Peripheral arterial disease is a source of morbidity and mortality. Surgical vascular reconstruction is a treatment option but probability of failure and complications are important concerns. In this study, we evaluated outcome of surgical infrainguinal reconstruction and factors affecting graft patency for a period of one year. Methods: In this cohort study, 85 consecutive patie...
متن کاملMetallic Stent Placement in Hemodialysis Graft Patients after Insufficient Balloon Dilation
OBJECTIVE We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. MATERIALS AND METHODS Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metalli...
متن کاملارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلیمتری در اندام فوقانی و مقایسه آنها با گرافت گورتکس 8 میلیمتری اندام تحتانی در یک سال اول پس از عمل
Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...
متن کاملImpact of Patient and Target-Vessel Characteristics on Arterial and Venous Bypass Graft Patency Insight From a Randomized Trial
Background—The purpose of this investigation was to determine optimal patient and target-vessel characteristics to maximize arterial and venous graft patency on the basis of data from a large clinical trial. Methods and Results—Angiographic data on 440 radial artery grafts and 440 saphenous vein grafts were analyzed with methodology to account for within-patient clustering. Multivariable models...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013