Platelet-based MPLE Algorithm for Denoising of SPECT Images: Phantom and Patient Study

نویسندگان

  • Abbas Takavar
  • Mehdi Sohrabi
  • Ahmad Bitarafan Rajabi
چکیده

Introduction: In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poisson noise and inherent smoothness of this kind of images. Methods: We applied this approach on both simulated and real SPECT images. Monte Carlo simulations were generated with the SIMSET package to model the physical processes and instrumentation used in emission imaging. Cardiac, brain and NEMA phantom SPECT images were obtained using a single-head, Argus model SPECT system. The performance of this method has been evaluated both qualitatively and quantitatively with power spectrum, SNR and noise level measurements on simulated and real SPECT images. Results: For NEMA phantom images, the measured noise levels before (Mb) and after (Ma) denoising with Platelet-based MPLE approach were Mb=2.1732, Ma=0.1399. In patient study for 32 cardiac SPECT images, the difference between noise level and SNR before and after the approach were (Mb=3.7607, SNRb=9.7762, Ma=0.7374, SNRa=41.0848) respectively. Thus the Coefficient of variance (C.V) of SNR values for denoised images with this algorithm as compared with Butterworth filter, (145/33%) was found. For 32 brain SPECT images the Coefficient Variance of SNR values, (196/17%) was obtained. Conclusion: Our results shows that, Platelet-based MPLE is a useful method for denoising SPECT images considering better homogenous image, improvements in SNR, better radioactive uptake in target organ and reduction of interfering activity from background radiation in comparison to that of other conventional denoising methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platelet-based MPLE algorithm for denoising of SPECT images: phantom and patient study

Introduction: In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poi...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007