Hemodynamic changes following correction of severe aortic stenosis using the Cutter-Smeloff prosthesis.

نویسندگان

  • S J Lee
  • M Haraphongse
  • J C Callaghan
  • R E Rossall
  • R S Fraser
چکیده

Twelve patients with pure or dominant stenosis were studied before and after aortic valve replacement (Cutter-Smeloff). The changes in cardiac output and A-V O2 difference were small and insignificant, but exercise stroke volume increased from 72 to 96 ml after the surgery. The aortic peak systolic gradient was 92 +/- 29 mm Hg before and 4 +/- 9.8 mm Hg after surgery. The PA wedge pressure, taken as a measure of the LV diastolic pressure, decreased from 18 mm Hg to 12 mm Hg at rest and 30 mm Hg to 16 mm Hg on exercise. The PA pressures also decreased from 37/18 (mean, 26) to 28/11 (17) mm Hg at rest, and 61/31 (43) to 41/17 (27) mm Hg on exercise, but the PA and PA wedge pressures maintained their tendency to increase in a linear manner with oxygen consumption (Vo2) on exercise after surgery. As a result of decreased wedge pressure, the pulmonary vascular resistance also decreased significantly afterward. The adequacy of cardiac output at rest and on exercise expressed by cardiac output as the linear function of Vo2 improved toward the normal (values before operation, CO = 2.78 + 0.0069 Vo2, r = 0.84; after operation, CO = 3.80 + 0.0062 Vo2, r = 0.91). The exercise factor (delta CO/delta Vo2) or the regression coefficient, however, was similar before and after surgery. The hemodynamic result was satisfactory although some abnormalities of the left ventricular function persisted after operation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Malfunction of the mitral valve prosthesis (Cutter-Smeloff). Clinical and hemodynamic observations in three cases.

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

متن کامل

Malfunction of the Mitral Valve Prosthesis (Cutter-Smeloff)

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

متن کامل

Postpartum patient with thrombosis of mechanical prostheses and acquired supravalvular aortic stenosis.

The blood hypercoagulability in pregnancy increases significantly the incidence of thrombosis of mechanical valves. Acquired supravalvular aortic stenosis is extremely rare. We report the case of an immediate postpartum patient with aortic mechanical prostheses and acquired supravalvular aortic stenosis who underwent emergency heart surgery, with severe hemodynamic instability, using adapted su...

متن کامل

Stent-based, off-pump creation of an apico-aortic conduit.

An apico-aortic conduit (AAC) is an alternative therapy in patients with aortic valve stenosis and severe concomitant disease. We investigated whether it is feasible to create an apico-aortic conduit off-pump with a newly developed, stent-based coring- and cannulation-device in the animal model. A new self-expandable, stent equipped and hooked prosthesis and a sheath enabling both airtight remo...

متن کامل

Clinical Outcomes and Imaging Findings in Women Undergoing TAVR.

Transcatheter aortic valve replacement (TAVR) has become the standard of care for patients with hemodynamically severe aortic stenosis who are symptomatic but deemed too high risk for surgery. Recent reports suggest that sex differences exist in outcomes following TAVR and in the diagnostic imaging evaluation of patients being considered for TAVR. In this review, the authors explore the differe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 1970