Computer-assisted three-dimensional volumetry of the human pulmonary acini.

نویسندگان

  • H Kitaoka
  • H Itoh
چکیده

Computer-aided three-dimensional (3-D) volumetry of human pulmonary acini was undertaken using the left upper lobe of a 51-year-old female operated for small lung cancer. A normal part of this lobe, fixed by intrabronchial infusion with a mixture of polyethylene glycol and formalin, was subjected to serial sectioning, using a special slicer, into 48 serial slices of 0.5 mm in thickness. A soft x-ray radiograph was prepared from each slice at x 12, and the contours of airways and acinar boundaries contained in it were input by digitization into a microcomputer for 3-D reconstruction and volumetry. The estimated volumes of 130 acini were unexpectedly uniform, showing a normal type distribution with a mean of 172.7 +/- 37.9 mm3. No significant correlation proved to exist between the volume of acini and the number of branching generation of the terminal bronchioles (TBs) they received. Furthermore, there was no significant difference in volume among the acini facing the costal surface, those facing the mediastinal surface and those not facing any pleural surface. However, the generation number of TBs was shown to differ significantly with the location of acini. These results suggest that the tree of conductive airways is designed so as to meet the requirement of constant acinar volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Analysis of the Human Ligamentous Lumber Spine-From Computer-Assisted Tomography to Finite Element Analysis

Detailed investigation on biomechanics of a complex structure such as the human lumbar spine requires the use of advanced computer-based technique for both the geometrical reconstruction and the stress analysis. In the present study, the computer-assisted tomography (CAT) and finite element method (FEM) are merged to perform detailed three dimensional nonlinear analysis of the human ligamentous...

متن کامل

A New Computer-Aided Detection System for Pulmonary Nodule in CT Scan Images of Cancerous Patients

Introduction: In the lung cancers, a computer-aided detection system that is capable of detecting very small glands in high volume of CT images is very useful.This study provided a novelsystem for detection of pulmonary nodules in CT image. Methods: In a case-control study, CT scans of the chest of 20 patients referred to Yazd Social Security Hospital were examined. In the two-dimensional and ...

متن کامل

Computer-Assisted Instruction (CAI), Virtual Patients (VP), and Human Patient Simulation (HPS) in Medical Education Based on Gagne’s Educational Design Pattern

Background and objectives: Educational technology is widely used in all parts of medical education. The use and application of common educational technologies and adoption of educational design patterns in medical sciences education can greatly help in medical simulations, training, and improving of clinical skills of nurses and medical students. The aim of this research was to study computer-a...

متن کامل

Ultrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume

Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...

متن کامل

Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study

OBJECTIVE To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. MATERIALS AND METHODS A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Tohoku journal of experimental medicine

دوره 167 1  شماره 

صفحات  -

تاریخ انتشار 1992