Assessment of the Stylohyoid Complex with Cone Beam Computed Tomography
نویسندگان
چکیده
BACKGROUND Orientation of the stylohyoid complex (SHC) may be important for evaluation of the patient with orofacial pain or dysphagia. OBJECTIVES Our purpose was to assess the length and angulations of SHC using cone beam computed tomography (CBCT). PATIENTS AND METHODS In this study, 3D images provided by CBCT of 69 patients (36 females, 33 males, age range 15-77 years) were retrospectively evaluated. All CBCT images were performed because of other indications. None of the patients had symptoms of ossified SHC. The length and the thickness of SHC ossification, the anteroposterior angle (APA) and the mediolateral angle (MLA) were measured by maxillofacial radiologists on the anteroposterior, right lateral and left lateral views of CBCT. Student's t test, Pearson's correlation and Chi-square test tests were used for statistical analysis. RESULTS According to the results, the mean length of SHC was 25.3 ± 11.3 mm and the mean thickness of SHC was 4.8 ± 1.8 mm in the study group. The mean APA value of SHCs was 25.6° ± 5.4° and the mean MLA value was 66.4° ± 6.7°. A positive correlation coefficient was found between age and APA (r = 0.335; P < 0.01); between thickness and APA (r = 0.448; P < 0.01) and also between length and thickness was found (r=0.236). CONCLUSION The size and morphology of the SHC can be easily assessed by 3D views provided by CBCT. In CBCT evaluation of the head and neck region, the radiologist should consider SHC according to these variations, which may have clinical importance.
منابع مشابه
Assessment of stylohyoid ligament in patients with Eagle’s syndrome and patients with asymptomatic elongated styloid process: A cone-beam computed tomography study
BACKGROUND AND AIM: This study was performed to evaluate and compare the calcification patterns of the stylohyoid ligament in Eagle’s syndrome (ES) patients, and asymptomatic patients with elongated styloid process (SP) via cone-beam computed tomography (CBCT).METHODS: A total of 52 CBCT images in two symptomatic (ES) and asymptomatic groups (n = 26 per group) were assessed. The mean length an...
متن کاملمقایسه دقت توموگرافی سهبعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماریهای سینوس پارانازال
Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...
متن کاملAsymptomatic bilateral calcified stylohyoid ligaments detection by panoramic radiography and cone beam computerized tomography
Stylohyoid ligaments calcified are found incidentally through imaging. Morphological characteristics can determine the development of different pathological compression levels of the head and neck. We report a case of an asymptomatic bilateral calcification of stylohyoid ligaments visualized by panoramic radiography and cone beam computerized tomography reconstruction. The correct description a...
متن کاملForeign Body in Nasal Cavity: Panoramic and Cone-Beam Computed Tomography (CBCT) Findings
Introduction: Panoramic view as a routine dental radiograph has an important role in diagnosis of other facial abnormalities accompanied with dento- alveolar structures. In this case presentation, we discuss this subject and also the efficacy of cone-beam computed tomography in localization of foreign body in complex anatomy of nasal cavity.
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2012