Quantification of circulating steroids in individual zebrafish using stacking to achieve nanomolar detection limits with capillary electrophoresis and UV-visible absorbance detection

نویسندگان

  • Vincent T. Nyakubaya
  • Brandon C. Durney
  • Marriah C. G. Ellington
  • Amber D. Kantes
  • Paige A. Reed
  • Shaylyn E. Walter
  • Jennifer Ripley Stueckle
  • Lisa A. Holland
چکیده

Capillary electrophoresis and UV-visible absorbance detection are used with sample stacking to achieve detection limits ranging from 0.2 to 2 ng/mL (0.8 to 6 nM) for steroids. Stacking is accomplished using negatively charged cyclodextrin steroid-carrier molecules at a discrete pH interface between the reconstituted sample and the separation electrolyte. Steroids are then separated in under 5 min using capillary electrophoresis that incorporates secondary equilibria via sodium dodecyl sulfate and cyclodextrin. The effectiveness of the method for measurements of multiple steroids in limited sample volumes is demonstrated in individual female fish with total circulating blood volumes of 5 μL or less. Steroid recoveries from plasma following a sample processing method developed with commercial extraction cartridges range from 81 to 109 % for 17α,20β-dihydroxy-pregn-4-en-3-one, testosterone, 11-ketotestosterone, estrone, 17β-estradiol, and 17α-ethinyl estradiol. When applied to reproductively active female zebrafish, changes were detected in the levels of circulating steroids as a result of exposure to different solvents and 17β-estradiol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromato...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 407  شماره 

صفحات  -

تاریخ انتشار 2015