Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end

نویسندگان

  • Soo J. Phee
  • S. C. Low
  • Paolo Dario
  • Arianna Menciassi
چکیده

Tendon sheath actuation is found in many applications, particularly in robotic hands and surgical robots. Due to the friction between the tendon and sheath, many undesirable characteristic such as backlash, hysteresis and non-linearity are present. It is desirable to know the end-effector force and elongation of the tendon to control the system effectively, but it is not always feasible to fix sensors at the end effector. A method to estimate the end-effector parameters using only a force and position sensor at the proximal site is given. An analytical study is presented and experiments are reported to support the result, showing a maximum full-scale error of approximately 7%. This result is achieved if the shape of the sheath remains the same and buckling is negligible. The results presented in this study could contribute towards haptic development in robotics surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Reconstruction of Nerve Defects Using Distraction Neurogenesis with a New Experimental Device

Introduction: Repair of peripheral nerve injuries is an intensive area of challenge and research in modern reconstructive microsurgery. Intensive research is being carried out to develop effective alternatives to the standard nerve autografting, avoiding its drawbacks. The aim of the study was to evaluate the effectiveness of a newly designed mechanical device for the reconstruction of the...

متن کامل

Variation in median nerve nutritional artery at the distal end of forearm: case report

Background: The median nerve is one of the most important branches of the brachial plexus. Due to the role of the median nerve in sensory and motor innervation of the forearm and hand in the upper limbs, its blood supply is very important. Awareness of variations in the blood supply pattern to this nerve reduces the incidence of necrosis and ischemia of the nerve during surgical and diagnostic ...

متن کامل

Myofascial force transmission: muscle relative position and length determine agonist and synergist muscle force.

Equal proximal and distal lengthening of rat extensor digitorum longus (EDL) were studied. Tibialis anterior, extensor hallucis longus, and EDL were active maximally. The connective tissues around these muscle bellies were left intact. Proximal EDL forces differed from distal forces, indicating myofascial force transmission to structures other than the tendons. Higher EDL distal force was exert...

متن کامل

Simultaneous Dorsal Base Fracture and FDP Avulsion of Distal Phalanx of the Little Finger

Avulsion injury of the flexor digitorum profundus (FDP) with concomitant fracture of the distal phalanx dorsal base is uncommon. Simultaneous avulsion fractures of the insertion of this tendon associated with rupture of the tendon from the bony fragment and combination with dorsal base fracture is very rare and also complicated. A 36- year- old man fell and injured his right little finger. FDP ...

متن کامل

Performance Control of Tendon-Driven Endoscopic Surgical Robots With Friction and Hysteresis

In this study, a new position control scheme for the tendon-sheath mechanism (TSM) which is used in flexible medical devices is presented. TSM is widely used in dexterous robotic applications because it can flexibly work in limited space, in constrained environments, and provides efficient power transmission from the external actuator to the distal joint. However, nonlinearities from friction a...

متن کامل