Accuracy of intraocular lens power calculation in pediatric cataracts with less than a 20 mm axial length of the eye.

نویسندگان

  • P Joshi
  • R Mehta
  • Suma Ganesh
چکیده

INTRODUCTION Selection of an appropriately-powered IOL is a complex issue, especially in eyes with an axial length of less than 20 mm in pediatric cataract. OBJECTIVE To assess the accuracy of IOL power calculation formulae in pediatric cataracts in eyes with an axial length of less than 20 mm. MATERIALS AND METHODS The records of children less than 15 years old with congenital cataract who had undergone primary IOL implantation were analyzed. MAIN OUTCOME MEASURES The variables studied were axial length, keratometric values and the prediction error. The data were analyzed for prediction error determination using the SRK II, SRK T, Holladay 1 and Hoffer Q IOL power calculation formulae. The formula that gave the best prediction error was identified. RESULTS Twenty-eight eyes of 19 children were included in the study. The absolute prediction error was found to be 1.84 ± 2.09 diopters (D) with SRK II, 2.93±3.55D with SRK T, 3.63±4.06D with Holladay 1, and 4.83±5.02D with Hoffer Q. The number of eyes with the absolute prediction error within 0.5 D was 6 (21.42%) with SRK II, 4 (14.28%) with SRK T, 1 (3.57%) with Holladay 1, and 3 (10.71%) with Hoffer Q. The absolute prediction error with SRK II formula was significantly better than that with other formulae (P less than .001). The axial length influenced the absolute prediction error with Hoffer Q formula (P = 0.04). The mean keratometry influenced the prediction error with SRK T formula (P = 0.02), Holladay 1 formula (P = 0.02) and Hoffer Q formula (P = 0.02). CONCLUSION Although the absolute prediction error tends to remain high with all the present IOL power calculation formulae, SRK II was the most predictable formula in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study

Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...

متن کامل

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

Factors Affecting the Accuracy of Intraocular Lens Power Calculation with Lenstar

This retrospective study was performed to compare refractive outcomes measured by conventional methods and by use of the Lenstar biometer and to investigate the factors affecting intraocular lens (IOL) power calculation with Lenstar with and without IOL-constant optimization. The study included 100 eyes of 86 patients who underwent cataract surgery. Corneal curvature was measured with a manual ...

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.

Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH

دوره 6 11  شماره 

صفحات  -

تاریخ انتشار 2014