Tibial component rotation assessment using CT scan in medial and lateral unicompartmental knee arthroplasty.
نویسندگان
چکیده
BACKGROUND Rotation of tibial component has not been analysed in literature for unicompartmental knee arthroplasty. The purpose of the study was to determine and compare the rotation of medial and lateral unicompartmental knee arthroplasty (UKA) tibial components. We assumed both components (lateral and medial) were positioned with external rotation. PATIENTS AND METHODS Eighteen lateral and 19 medial UKA patients were scanned postoperatively in neutral position with computed tomography enabling lower extremity three-dimensional image acquisition from the hip to the ankle. All the patients were operated by three different senior surgeons using the same surgical technique. From the reconstructions we measured the two-dimensional (2D) rotation of the tibial components. RESULTS The rotation of the tibial component was external (mean 6.5°, SD 5.1°) for the medial UKA and external (mean 7.3°, SD 10.3°) as well for the lateral UKA. The difference was statistically insignificant (P=0.717). DISCUSSION This study presents the first 2D in vivo analysis accurately determining and comparing medial and lateral UKA component rotation. Despite a wide range of value, we found both components were indeed externally rotated. The variability in implant positioning was observed despite the rigorous performance of an experienced surgeon using routine techniques in patients selected under routine criteria. Further analysis of these patients for satisfaction and implant survivorship in relation to implant rotation may give us an optimal range for the tibial component. If it is found that this ideal range cannot be consistently obtained with current surgical techniques then there may be a case for the use of a navigation system.
منابع مشابه
Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty.
Implant positioning and knee alignment are two primary goals of successful unicompartmental knee arthroplasty. This prospective study outlines the radiographic results following 32 patient-specific unicompartmental medial resurfacing knee arthroplasties. By means of standardized pre- and postoperative radiographs of the knee in strictly AP and lateral view, AP weight bearing long leg images as ...
متن کاملMeniscal Bearing Dislocation of Unicompartmental Knee Arthroplasty with Faint Symptom
We experienced two cases of atypical lateral dislocations of meniscal bearing in UKA (unicompartmental knee arthroplasty) without manifest symptoms. The dislocated bearing, which jumped onto the wall of tibial components, was found on radiographs in periodic medical examination although they could walk. Two thicker size bearing exchanges were promptly performed before metallosis and loosening o...
متن کاملUnicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?
Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis. Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...
متن کاملAn analysis of dislocation of the domed Oxford Lateral Unicompartmental Knee Replacement.
BACKGROUND The Oxford Unicompartmental Knee Replacement (OUKR) uses a mobile bearing to minimise wear. Bearing dislocation is a problem in the lateral compartment as the ligaments are loose in flexion. A domed tibial component has been introduced to minimise the risk of dislocation, yet they still occur, particularly medially. The aim of this mechanical study was to compare the domed and flat t...
متن کاملMeasurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopaedics & traumatology, surgery & research : OTSR
دوره 97 3 شماره
صفحات -
تاریخ انتشار 2011