Reference values for mitral and tricuspid annular dimensions using two-dimensional echocardiography

نویسندگان

  • Girish Dwivedi
  • Ganadevan Mahadevan
  • Donie Jimenez
  • Michael Frenneaux
  • Richard P Steeds
چکیده

Only limited data are available from which normal ranges of mitral annular (MA) and tricuspid annular (TA) dimensions have been established. Normative data are important to assist the echocardiographer in defining the mechanism of atrioventricular valve regurgitation and to inform surgical planning. This study was conceived to establish normal MA and TA dimensions. Consecutive healthy subjects over the age of 60 were randomly recruited from the community as part of a screening project within South Birmingham. MA and TA dimensions in end-systole and end-diastole were evaluated in the parasternal and apical acoustic windows views using transthoracic echocardiography. Gender (males (M) and females (F))-specific dimensions were then assessed. A total of 554 subjects were screened and 74 with pathology considered to have an effect on annular dimensions were excluded from analysis. The mean age of the remaining 480 subjects was 70±7 years and the majority were female (56%). Dimensions were larger in men than in women and greater at end-diastole than end-systole (both P<0.05). Mean MA diameters at end-systole in the parasternal long axis view (cm) were 3.44 cm (M) and 3.11 cm (F) and at end-diastole 3.15 cm (M) and 2.83 cm (F) respectively. Mean TA diameters (cm) at end-systole in the apical 4 chamber view were 2.84 (M) and 2.80 (F) and at end-diastole 3.15 (M) and 3.01 (F) respectively. The reference ranges derived from this study differ from current published standards and should help to improve distinction of normal from pathological findings, in identifying aetiology and defining the mechanism of regurgitation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Normal Echocardiographic Measurements in a Korean Population Study: Part II. Doppler and Tissue Doppler Imaging

BACKGROUND Hemodynamic and functional evaluation with Doppler and tissue Doppler study as a part of comprehensive echocardiography is essential but normal reference values have never been reported from Korean normal population especially according to age and sex. METHODS Using Normal echOcaRdiographic Measurements in a KoreAn popuLation study subjects, we obtained normal reference values for ...

متن کامل

The tricuspid valve annulus: study of size and motion in normal subjects and in patients with tricuspid regurgitation.

The tricuspid valve leaflets and their annular attachments were recorded by two-dimensional echocardiography from a view of the right ventricular inflow tract obtained by placing the transducer at an intermediate position between the left ventricular apex and the left lower sternal border. The transducer was rotated, and recordings were made at 30 degrees rotational intervals around the circumf...

متن کامل

Association of mitral annular calcification and aortic valve morphology: a substudy of the aortic stenosis progression observation measuring effects of rosuvastatin (ASTRONOMER) study.

AIMS Mitral annular calcification (MAC) is characterized by calcium and lipid deposition in the annular fibrosa of the mitral valve. Although individuals with MAC are at increased risk of cardiovascular events, little is known about the significance of this finding in patients with concurrent aortic stenosis (AS). The aim of this study was to describe the association of baseline MAC and aortic ...

متن کامل

Right heart assessment by echocardiography: gender and body size matters.

BACKGROUND Published reference values for echocardiographic measurements of right-heart dimensions and function do not stratify for gender and body size. The aim of this study was therefore to assess the impact of gender and biometric characteristics on right-heart dimensions and function. METHODS From the echocardiography database at a tertiary care center, 1,625 subjects (mean age, 44 ± 14 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014