Randomized evaluation of the TriActiv balloon-protection flush and extraction system for the treatment of saphenous vein graft disease.

نویسندگان

  • Joseph P Carrozza
  • Michael Mumma
  • Jeffrey A Breall
  • Aland Fernandez
  • Eugene Heyman
  • Christopher Metzger
چکیده

OBJECTIVES The Protection During Saphenous Vein Graft Intervention to Prevent Distal Embolization (PRIDE) study compared outcomes with the TriActiv System (Kensey Nash Corp., Exton, Pennsylvania), a balloon-protection flush and extraction device, with an embolic protection group during treatment of saphenous venous grafts (SVGs). BACKGROUND Treatment of SVGs with embolic protection reduces adverse cardiac events. METHODS We conducted a prospective trial randomizing 631 patients with coronary ischemia and lesions in SVGs to embolic protection with the TriActiv System or control group (Guardwire System [Medtronic AVE, Santa Rosa, California] or Filterwire EX [Boston Scientific Corp., Maple Grove, Minnesota]). RESULTS The incidence of major adverse cardiac events at 30 days was 11.2% for the TriActiv group and 10.1% for the control group (relative risk = 1.1%; 95% confidence interval 0.67 to 1.76; p = 0.65; p = 0.02 for non-inferiority). Safety and efficacy end points were similar between groups except that patients randomized to the TriActiv System had more hemorrhagic complications (10.9% vs. 5.4%; p = 0.01). CONCLUSIONS The TriActiv System was not inferior to approved embolic protection devices for the treatment of diseased SVGs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

Adjuvant therapy of breast cancer in the elderly: does one size fit all?

6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...

متن کامل

Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts.

BACKGROUND The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for t...

متن کامل

Comparison of therapeutic results of large saphenous vein resection with conventional methods and standard bridging

                                                                 Background: The use of the traditional method for saphenous vein harvesting is associated with wound complications and not on-time patient mobilization. This has caused the improvement of minimally invasive vein harvesting techniques, together with general bridging. This study was designed to compare the therapeutic results of...

متن کامل

Saphenous Vein Graft Dissection Using the GuardWire Distal Protection Balloon

The higher rate of periprocedural adverse events and lower rate of event-free survival of saphenous vein graft (SVG) intervention compared with native coronary artery intervention is primarily due to distal embolization. Distal embolic protection devices have been shown to reduce the incidence of no flow/slow flow and procedure related myocardial infarction during percutaneous intervention of d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 46 9  شماره 

صفحات  -