Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.

نویسندگان

  • B M Weiss
  • D R Spahn
  • H Rahmig
  • R Rohling
  • T Pasch
چکیده

Radial artery tonometry provides continuous measurement of non-invasive arterial pressure (CNAP) by a sensor positioned above the radial artery. An inflatable upper arm cuff enables intermittent oscillometric calibration. CNAP was compared with invasive radial artery pressure recordings from the opposite wrist in 22 high-risk surgical patients with an inter-arm oscillometric mean arterial pressure difference < or = 10 mm Hg. Oscillometric, tonometric and invasive digital pressure values, and invasive and CNAP waveforms were obtained by the same instrument (Colin BP-508). Correlation coefficients (r) of invasive vs oscillometric values (n = 481 pairs) were 0.83, 0.90 and 0.92, and mean absolute errors of oscillometry were 7.6, 4.7, and 2.6 mm Hg for systolic, diastolic and mean arterial pressures, respectively. Correlation was poor for systolic (r = 0.80), diastolic (r = 0.77) and mean (r = 0.84) invasive vs CNAP values (n = 1375). Compared with oscillometry, mean absolute errors of 15.2, 10.9 and 9.4 mm Hg for systolic, diastolic and mean CNAP, respectively, were significantly (P < 0.001) higher. Mean prediction errors of CNAP, compared with invasive values, were -5.8 (SD 14.2) mm Hg for systolic, +7.2 (8.3) mm Hg for diastolic and +3.9 (8.8) mm Hg for mean arterial pressure. Individual patient accuracy of CNAP was assessed as good (individual prediction error < or = 5 (8) mm Hg and individual absolute error < or = 10 mm Hg) in seven patients, as acceptable (< or = 10 (12) and < or = 15 mm Hg) in 11 patients, and as inadequate in four of 22 patients. Individual accuracy of oscillometry was good or acceptable in all 22 patients. The trend in CNAP changes (difference between consecutive measurements) was sufficiently accurate during induction of anaesthesia, as only 47 (7.6%), 14 (2.3%) and 27 (4.4%) of 616 systolic, diastolic and mean CNAP values differed by more than 10 mm Hg of invasive pressure trends. We conclude that: intermittent oscillometry provides accurate arterial pressure monitoring; CNAP measurements offer a reliable trend indicator of pressure changes during induction of anaesthesia and may be considered an alternative to invasive pressure measurements, should arterial cannulation be difficult in an awake patient; and accuracy of absolute CNAP values is only moderate and unpredictable, thus radial artery tonometry should not replace invasive monitoring in high-risk patients during major surgical procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of central aortic pressure by SphygmoCor requires intra-arterial peripheral pressures.

Central arterial pressure, measured close to the heart, may be of more patho-physiological importance than conventional non-invasive cuff blood pressure. The technique of applanation tonometry using SphygmoCor has been proposed as a non-invasive method of estimating central pressure. This relies on mathematically derived generalized transfer functions, which have been previously validated using...

متن کامل

Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices.

The MediWatch is a wrist-mounted noninvasive blood pressure monitor designed to capture the radial pulse waveform using arterial tonometry and yield blood pressure measurements when the waveform is calibrated. An early prototype of this monitor uses a pulse-sensing system with a cylindrical plunger to applanate the radial artery. This prototype was evaluated against simulated blood pressure gen...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Calibration of noninvasively recorded upper-limb pressure waves.

Calibration of Noninvasively Recorded Upper-Limb Pressure Waves To the Editor: The article by Verbeke et al1 raises an important question: how does one calibrate the radial artery waveform obtained by applanation tonometry? Does one apply systolic and diastolic brachial values from the Korotkov technique, the “gold standard”, or does one use an oscillometric wrist technique, despite lack of con...

متن کامل

Central aortic blood pressure from ultrasound wall-tracking of the carotid artery in children: comparison with invasive measurements and radial tonometry.

Differences between central aortic root (c) and peripheral (p) systolic blood pressure (SBP) may be particularly marked in children, but noninvasive methods for assessing cSBP in children have not been validated. We compared estimates of cSBP obtained from radiofrequency ultrasound wall tracking of the carotid artery (ART.LAB system) with that measured directly by a catheter in the aortic root ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 76 3  شماره 

صفحات  -

تاریخ انتشار 1996