Multiplex enzyme assay for galactosemia using ultraperformance liquid chromatography-tandem mass spectrometry.

نویسندگان

  • Dae-Hyun Ko
  • Sun-Hee Jun
  • Hyung-Doo Park
  • Sang Hoon Song
  • Kyoung Un Park
  • Jin Q Kim
  • Young-Han Song
  • Junghan Song
چکیده

BACKGROUND Galactosemia is one of the most important inherited disorders detected by newborn screening tests. Abnormal results in screening tests should be confirmed by enzyme activity assays, but existing methods are time and labor intensive. We developed a novel multiplex enzyme assay for galactosemia using ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). METHODS [(13)C6]-galactose, [(13)C2]-galactose-1-phosphate, and UDP-glucose were used as substrates for 3 galactose-metabolizing enzymes. The end products from the combined reaction mixtures, [(13)C6]-galactose-1-phosphate, UDP-[(13)C2]-galactose, and UDP-galactose, were simultaneously measured using UPLC-MS/MS. Linearity, imprecision, ion suppression, and the effects of substrate were evaluated to determine assay performance. Enzyme activities from 35 healthy individuals, 8 patients with enzyme deficiency, and 18 mutant cells were analyzed. RESULTS Substrates, products, and internal standards from the mixture of 3 enzyme reactions were clearly separated by using UPLC-MS/MS, with an injection cycle time of 10 min. Ion suppression was 0.1%-2.5%, the interassay imprecision of UPLC-MS/MS was 3.3%-10.6% CV, and the linearity of each system was good (R(2) = 0.994-0.999). Patient samples and mutated cells showed consistently low enzyme activities compared with those of normal individuals and wild-type cells. CONCLUSIONS This method allows for a high-throughput and reproducible multiplex enzyme assay for galactosemia in erythrocytes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Relative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation

The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...

متن کامل

A Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers

An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2010