Tissue oxygenation monitoring using resonance Raman spectroscopy during hemorrhage.
نویسندگان
چکیده
BACKGROUND The ability to monitor the patient of hemorrhage noninvasively remains a challenge. We examined the ability of resonance Raman spectroscopy to monitor tissue hemoglobin oxygenation (RRS-StO2) during hemorrhage and compared its performance with conventional invasive mixed venous (SmvO2) and central venous (ScvO2) hemoglobin oxygen saturation as well as with near-infrared spectroscopy tissue hemoglobin oxygenation (NIRS-StO2). METHODS Five male swine were anesthetized and instrumented followed by hemorrhage at a rate of 30 mL/min for 60 minutes. RRS-StO2 was continuously measured from the buccal mucosa, and NIRS-StO2 was continuously measured from the forelimb. Paired interval measures of SmvO2, ScvO2, and lactate were made. Pearson correlation was used to quantify the degree to which any two variables are related. Receiver operating characteristic (ROC) area under the curve values were used for pooled data for RRS-StO2, NIRS-StO2, SmvO2, and ScvO2 to compare performance in the ability of tissue oxygenation methods to predict the presence of an elevated arterial blood lactate level. RESULTS Sequential RRS-StO2 changes tracked changes in SmvO2 (r = 0.917; 95% confidence interval [CI], 0.867-0.949) and ScvO2 (r = 0.901; 95% CI, 0.828-0.944) during hemorrhage, while NIRS-StO2 failed to do so for SmvO2 (r = 0.283; 95% CI, 0.04919-0.4984) and ScvO2 (r = 0.142; 95% CI, -0.151 to 0.412). ROC curve performance of oxygenation measured to indicate lactate less than or greater than 3 mM yielded the following ROC area under the curve values: SmvO2 (1.0), ScvO2 (0.994), RRS-StO2 (0.972), and NIRS-StO2 (0.611). CONCLUSION RRS-StO2 seems to have significantly better ability to track central oxygenation measures during hemorrhage as well as to predict shock based on elevated lactate levels when compared with NIRS-StO2.
منابع مشابه
Cerebral Tissue Oxygenation during Immediate Neonatal Transition and Resuscitation
This article provides a review of cerebral tissue oxygenation during immediate transition after birth in human neonates. Recommended routine monitoring, especially if resuscitation is needed, during this period includes arterial oxygen saturation and heart rate measured by pulse oximetry and electrocardiogram. However, there is increasing interest to monitor in addition with near-infrared spect...
متن کاملContinuous assessment of cerebral autoregulation with near-infrared spectroscopy in adults after subarachnoid hemorrhage.
BACKGROUND AND PURPOSE In patients with subarachnoid hemorrhage, the assessment of cerebral autoregulation aids in prognosis as well as detection of vasospasm. Mx is a validated index of cerebral autoregulation based on measures of cerebral perfusion pressure and mean flow velocity on transcranial Doppler but is impractical for longer-term monitoring. Near-infrared spectroscopy is noninvasive a...
متن کاملSpectroscopic analysis of the oxygenation state of hemoglobin using coherent anti-Stokes Raman scattering.
A method for noninvasively determining blood oxygenation in individual vessels inside bulk tissue would provide a powerful tool for biomedical research. We explore the potential of coherent anti-Stokes Raman scattering (CARS) spectroscopy to provide this capability. Using the multiplex CARS approach, we measure the vibrational spectrum in hemoglobin solutions as a function of the oxygenation st...
متن کاملCorrection: Resonance Raman spectroscopy as an in situ probe for monitoring catalytic events in a Ru-porphyrin mediated amination reaction.
Correction for 'Resonance Raman spectroscopy as an in situ probe for monitoring catalytic events in a Ru-porphyrin mediated amination reaction' by Paolo Zardi et al., Analyst, 2016, 141, 3050-3058.
متن کاملApplication of Deep Uv Resonance Raman Spectroscopy to Bioprocessing
currently a relatively small percentage of conventional pharmaceuticals, continues to expand with predicted revenues of over USD 100 billion for 2010. With continual demand for high fidelity products, from recombinant therapeutic proteins to nucleic acid-based medicinal products, the need for reliable, cost effective and appropriate analytical techniques for assessing the conformity of the prod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of trauma and acute care surgery
دوره 76 2 شماره
صفحات -
تاریخ انتشار 2014