Transmission Efficiency Optimization for the operation of double-circuit Overhead Lines
نویسنده
چکیده
Nowadays the question of improving overhead-line (OHL) operation efficiency is more than ever considered as a very critical issue. This is because power losses have recently acquired an extra cost due to the CO2 release penalty. It is well known that a good portion of the electricity required to operate a power grid is spent as OHL power losses. In this paper the key points of the maximum OHL transmission-efficiency theory are reviewed. OHL loading enabling the maximum transmission efficiency is given. With a case study it is then shown how to optimize the double-circuit OHL transmission-efficiency for the periods of OHL off-peak loading. The OHL transmission-efficiency vs. OHL loading curves of the OHL is presented and the change in the character from capacitive to inductive with an increasing OHL load is illustrated. Potential transmissionefficiency gains in percentage points are calculated. Conclusions of practical importance are drawn both for OHL design purposes as well as for its operation optimization.
منابع مشابه
Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملمکان یابی خطا در شبکه های توزیع فشار متوسط دو مداره به روش امپدانسی
Power distribution feeders contains many laterals, sub-laterals, different number of circuit line, load taps, balanced and unbalanced load, different type of lines (cable or overhead), different cross-sections and numerous distribution transformers with different capacities. Moreover, the voltage and current are measured only at the beginning of the feeder. Thus, fault location is very complex....
متن کاملFault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method
In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...
متن کاملApplication of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملDesign Optimization and Construction of Double-Sided Linear Induction Motor
Linear induction motors have single and double-sided structures which are used in special applications, according to their advantages and disadvantages. Due to advantages such as lack of normal forces in double-sided type, these motors are more controllable and popular than the single-sided type, especially for transportation applications. In literature, single-sided linear induction motors ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -