Amide Proton Transfer Imaging with Improved Robustness to Magnetic Field Inhomogeneity
نویسندگان
چکیده
Introduction Amide proton transfer (APT) imaging is an application of chemical exchange saturation transfer (CEST) imaging that generates contrast from exchangeable protons on the backbone of endogeneous mobile proteins and peptides. In a conventional APT experiment, a label image is acquired with RF irradiation of amide protons at 3.5ppm, and subtracted from a reference image with RF irradiation at -3.5ppm. This asymmetry analysis allows quantification the CEST effect while correcting for direct water saturation due to RF spillover. However, because the asymmetry analysis is dependent on the reference and label scan being applied at symmetric frequencies around the water line, it is very sensitive to B0 inhomogeneities. Initial in-vivo human brain APT images have produced poor results near the ears and sinuses where air-tissue interfaces lead to susceptibility artifacts, unless specialized B0 inhomogeneity correction methods are used. In addition, asymmetry analysis fails to separate the APT contrast from the intrinsic magnetization transfer (MT) asymmetry, and therefore, APT weighted images still reflect the MT properties of white and gray matter. In this abstract we propose a novel alternating frequency pulsed-RF saturation scheme for APT imaging combined with a 3-way subtraction that is less sensitive to B0 inhomogeneity than traditional asymmetry analysis and suppresses MT asymmetry effects. Methods Our subtraction strategy requires acquiring three images. One image [Ssat(+3.5ppm)] was acquired with all presaturation pulses applied at the amide proton frequency, a second with all pulses applied at minus the frequency [Ssat(-3.5ppm)], and a third with presaturation pulses of the same power alternating between both frequencies [Ssat(±3.5ppm)]. If power is sufficient, then both the single positive frequency and the dual frequency images should saturate the amide proton line. Subtracting 2x the dual frequency image from the sum of positive and negative frequency images should give a CEST signal equivalent to the positive frequency irradiation. Assuming off-resonance and MT effects are linear in power, they will subtract out, even if B0 shifts the line or MT is asymmetric. Below we refer to this subtraction approach as Saturation with Frequency Alternating Radiofrequency Irradiation (SAFARI). Healthy volunteers were imaged in a 3T GE SIGNA EXCITE scanner. The APT imaging sequence consisted of a 3 second pulsed-RF irradiation followed by a single shot EPI acquisition [TR=5s, TE=63.3ms , FOV=24cm, matrix=96x96, slice thickness=8mm ]. Several RF pulse trains were tested including 7.5ms inversion Hanning pulses repeated every TRRF=12.5ms, and inversion Blackman pulses with pw=[9ms, 15ms] and TRRF=[15ms, 25ms, 35ms, 50ms, 70ms, 100ms]. Forty-eight images were acquired for each SAFARI scan: 12 at positive frequency, 12 at negative frequency and 24 with alternating frequency preparations interleaved in time. In addition, one unsaturated S0 image was acquired for control. Total scan time was 3 minutes. The CEST effect was evaluated by conventional MT ratio asymmetry analysis: MTRasym=[Ssat(-3.5ppm)-Ssat (+3.5ppm)]/S0 and by SAFARI: MTRSAFARI=[ Ssat (+3.5ppm)+Ssat (-3.5ppm)-2 Ssat (±3.5ppm)]/ S0. To evaluate the robustness of the pulse sequence against B0 inhomogeneities, APT imaging was performed at 3.5ppm with and without a shift of irradiation frequencies by 100Hz (RF irradiation at +550Hz /350Hz vs. +450Hz/-450Hz, respectively). Results and Discussion Conventional MTRasym (Fig. 1A) shows a significant white-gray matter contrast that is reminiscent of MT imaging contrast. The MTRasym map has values ranging mostly between ±2%. Although this is similar to MTRasym values found in the literature, it does not match the positive signal predicted for APT imaging alone. Negative MTRasym values are likely due to the intrinsic MT asymmetry competing against the APT effect. In comparison, the proposed MTRSAFARI (Fig. 1C) method yields a significantly more homogeneous APT map that exhibits no white-gray matter contrast. The map has APT values in the +2% range. Taken together these results strongly suggest that the proposed alternating frequency method can separate the amide proton transfer ratio from the intrinsic MT asymmetry. MTRSAFARI also performs much better in the presence of B0 inhomogeneity than MTRasym. Fig. 2A shows a large susceptibility artifact above the sinuses that is corrected on the MTRSAFARI map (Fig. 1C). In the presence of a 100Hz B0 inhomogeneity across the entire field of view, MTRasym (Fig. 1B) completely fails at detecting the APT effect. Instead it is dominated by asymmetric RF spillover. In contrast, MTRSAFARI performs much better (Fig. 1D) and remains similar to the on-resonance MTRSAFARI map (Fig. 1C). The SAFARI pulse sequence was evaluated with several RF pulse trains. Fig. 2 shows that MTRasym maps are unchanged with varied RF pulse width and TRRF. As TRRF increases beyond the exchange time, the CEST contrast should decrease due to inefficient amide proton saturation. This was observed experimentally by increasing TRRF up to 100ms for a given RF pulse. Fig. 3 shows that the MTRSAFARI intensity for an ROI in the occipital cortex decreases by ~50% at long TRRF . If T1 were known the curve could be fitted to estimate the exchange rate. In conclusion, SAFARI APT imaging shows a clearer APT contrast free of the confounding MT asymmetry seen in traditional MTRasym analysis. It also is much more robust in the presence of B0 inhomogeneity and eliminates the need for specialized B0 correction. Finally, it might provide a novel strategy for measuring exchange rates in vivo. Further evaluation is needed to assess whether alternating frequency APT imaging will permit improved characterization of brain pathology in clinical applications.
منابع مشابه
Amide proton transfer imaging with improved robustness to magnetic field inhomogeneity and magnetization transfer asymmetry using saturation with frequency alternating RF irradiation.
Amide proton transfer (APT) imaging has shown promise as an indicator of tissue pH and as a marker for brain tumors. Sources of error in APT measurements include direct water saturation, and magnetization transfer (MT) from membranes and macromolecules. These are typically suppressed by postprocessing asymmetry analysis. However, this approach is strongly dependent on B(0) homogeneity and can i...
متن کاملNoninvasive amide proton transfer magnetic resonance imaging in evaluating the grading and cellularity of gliomas
Using noninvasive magnetic resonance imaging techniques to accurately evaluate the grading and cellularity of gliomas is beneficial for improving the patient outcomes. Amide proton transfer imaging is a noninvasive molecular magnetic resonance imaging technique based on chemical exchange saturation transfer mechanism that detects endogenous mobile proteins and peptides in biological tissues. Be...
متن کاملAlternate ascending/descending directional navigation approach for imaging magnetization transfer asymmetry.
A new method for imaging magnetization transfer (MT) asymmetry with no separate saturation pulse is proposed in this article. MT effects were generated from sequential two-dimensional balanced steady-state free precession imaging, where interslice MT asymmetry was separated from interslice blood flow and magnetic field inhomogeneity with alternate ascending/descending directional navigation (AL...
متن کاملMeasurement of Lactate Content and Amide Proton Transfer Values in the Basal Ganglia of a Neonatal Piglet Hypoxic-Ischemic Brain Injury Model Using MRI.
BACKGROUND AND PURPOSE As amide proton transfer imaging is sensitive to protein content and intracellular pH, it has been widely used in the nervous system, including brain tumors and stroke. This work aimed to measure the lactate content and amide proton transfer values in the basal ganglia of a neonatal piglet hypoxic-ischemic brain injury model by using MR spectroscopy and amide proton trans...
متن کاملDetection of Early Response to proteasome inhibitor treatment in a Rat Glioma Model with Amide Proton Transfer (APT) Imaging
INTRODUCTION Recently, a new magnetization transfer (MT)-based contrast mechanism for MRI, called chemical exchange-dependent saturation transfer (CEST), has emerged in the field of cellular and molecular imaging. This technique has now evolved into several different variants with nomenclature based on magnetic properties of new CEST contrast agents (diamagnetic and paramagnetic) and on the par...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009